IV — INSTALLATION

MOUNTING THE POWER SUPPLY.  

Refer to Figure

6 and insert HSF-1UR power supply in selected slot until
power supply front panel is flush with rack adapter chassis
and secure with two front panel mounting screws. 

CAUTION: Do not overtighten these screws: max.
torque is 2 in.-lbs (0.23 N x m).

CONNECTIONS. 

All connections are made at the rear

panel of the RA 19-1U Rack Adapter (see RA 19-1U
Operator Manual). Connect the load to the applicable ±
DC OUTPUT terminals. AC input power is applied via two

INPUT POWER terminal blocks: one supplying slots 2
and 4, the other supplying slots 1 and 3. Make sure to
connect the AC input Neutral, Line and Ground wires to
the respective terminals of the terminal blocks.

REMOVAL. 

To remove a power supply, first use the

POWER switch to turn off the unit. Then loosen the two
mounting screws and extract the unit from the RA 19-1U
Rack Adapter. 

CAUTION: The ON/OFF switch must be

set to OFF before removing the unit from the rack
adapter

.

V — OPERATION     

Turn the unit on using the front panel POWER switch (see
Figure 6). 

CAUTION: DO NOT repeatedly toggle the

POWER on/off switch as this may cause unit to fault.

 

When output voltage is available, the VDC ON LED is on

(green). For 100W and 150W 5V through 48V models the
VDC ON LED lights red to indicate a fan malfunction. The
100W 3.3V model and all 50W models use convection
cooling and do not include a fan.

While monitoring output voltage at the front panel test
points, the Output Voltage Adjust trimmer allows adjust-
ment of the output voltage. 

The 3.3V models do not use forced current sharing so the
MASTER ON LED is always off. The MASTER ON LED
for 5V through 48V models goes on under any of the three
following conditions:

• Independent operation.

• Operation in a parallel master/slave configuration 

to indicate which unit is the master.

• Operation in a parallel master/slave configuration

to indicate that a slave unit is no longer within the
proper specifications for paralleled units. Slave 1
should be optimally adjusted to 40mV less than
master, slave 2 adjusted to 40mV less than slave
1, etc. The maximum allowable difference
between paralleled units is 250mv. The minimum
allowable difference between paralleled units is
25mV. If a slave exceeds these limits, the MAS-
TER ON light goes on.

FIGURE 6.  COMPONENT LOCATIONS

3043412

POWER 
SWITCH

TEST 

POINTS

VOLTAGE 

ADJUST

TRIMMER

MASTER

ON

LED

VDC 

ON

LED

MOUNTING

SCREW

MOUNTING

SCREW

NOTE:  MOUNTING SCREW MAX TORQUE: 2 IN.-LBS. (0.23 N x m)

Содержание HSF 3.3-25-1UR

Страница 1: ...exter nal connections are made through the rack adapter refer to the RA 19 1U manual which is available for free down load at www kepcopower com support opmanls htm ra19 1u Seven models may be selecte...

Страница 2: ...operate at less than maximum reducing stress and increasing reliability of the system If one unit fails the remaining units will continue to supply the load and the load current will be divided equal...

Страница 3: ...eering Remote sensing is recommended For master slave operation to work properly each unit should be adjusted to 40 mV optimum less than the next paral leled unit unit 1 is adjusted to VOUT unit 2 to...

Страница 4: ...20 ms min DIELECTRIC STRENGTH at 15 to 35 C ambient 10 to 85 relative humidity Between input and output 3KV a c for one minute cutout current 10ma Between input and ground 2KV a c for one minute cuto...

Страница 5: ...ERATURE 40o C to 75o C RELATIVE HUMIDITY Operating and storage 10 to 95 wet bulb temp 35o C non condensing FUSE Quick acting 5 0A 250V 5 2 x 20mm Littelfuse P N 215005PF Kepco P N 541 0134 DIMENSIONS...

Страница 6: ...CAUTION DO NOT repeatedly toggle the POWER on off switch as this may cause unit to fault When output voltage is available the VDC ON LED is on green For 100W and 150W 5V through 48V models the VDC ON...

Страница 7: ...ERS 5 TOLERANCES UNLESS OTHERWISE SPECIFIED 3 PLACES 0 005 2 PLACES 0 01 FRACTIONS 1 64 SEE DETAIL B 1 732 44 0 0 010 0 3 4 295 109 1 0 140 3 6 0 076 1 9 1 131 28 7 0 471 12 0 0 780 19 8 3 960 100 6 0...

Отзывы: