FIGURE 1.  HSF-1UR 100 WATT POWER SUPPLIES (4) INSTALLED IN RA 19-1U RACK ADAPTER

II — FEATURES

FRONT PANEL ACCESS. 

 

The front panel provides a

power ON/OFF switch controlling input power and a “VDC
ON” light which indicates when the unit is operating.

NOTE: The ON/OFF switch must be set to OFF before
removing unit from rack adapter.

 The front panel “MAS-

TER ON” LED lights when 1) the unit operates indepen-
dently, or 2) the unit is used in parallel redundant
configurations while a) the output is less than 10% of
nominal or b) the output is within 10% to 100% of nominal
and the unit is functioning as a master. In parallel redun-
dant configurations, the module with the highest voltage
functions as the master. The other units are slaves, and
track the output voltage of the master. Refer to 

Current

Share Bus (CSB)

 on page 3 for details. (For the 3.3V

model, the “MASTER ON” LED has no function and is
always off.) The front panel Vadj trimmer provides adjust-
ment of the output voltage within the limits specified in
Table 1; test points connected to the +S and –S lines are
available at the front panel for measuring the output.

BUILT-IN OR-ING DIODES.  

OR-ing diodes allow

configuration of all models for hot-swap and parallel-
redundant N+1 operation where current distribution is not
equal and the idle unit takes over in the event of failure.

FORCED CURRENT SHARE CIRCUIT. 

(Not avail-

able on 3.3V model). When units are configured for N+1
parallel redundant operation, it is desirable (but not
required) for current to be divided equally among the paral-
leled supplies. When the CSB (forced Current Share Bus)
lines of paralleled HSF-1UR units are connected together,
the load current is forced to divide equally between all par-
alleled units; units operate at less than maximum, reducing
stress and increasing reliability of the system. If one unit
fails, the remaining units will continue to supply the load,
and the load current will be divided equally among the
remaining operating units. The failed unit is automatically
isolated from the circuit by a built-in isolation diode. Refer
to 

Current Share Bus (CSB)

 on page 3 for details.

REMOTE ON-OFF.  

Remote on-off (X and Y models

only) is via ±RC assigned to pins of the RA 19-1U I/O con-
nector: off = no voltage, short circuit, or 0 to 0.8V, on = 4.5
to 12.5V (or 12.5 to 24.5V via 1.5K Ohms). To reverse on-
off polarity contact Kepco. There is no isolation between
±RC, d-c output and alarm circuit. Refer to the RA 19-1U
Manual for details.

CURRENT MONITOR. 

Current monitor (C and Y

models only) is via ±IMON assigned to pins of the RA 19-
(X)B I/O connector. Monitored Output Current (Amps) =
Voltage drop across R

EQ

 (mVolts) / R

EQ

 (mOhms) where

R

EQ

 is the sum of R

S

 (see Table 1) + trace resistance to

point where current monitor is connected, approximately
4mOhms. The voltage drop across R

EQ

 is measured

across ± IMON pins (requires millivoltmeter, range 0 to
250mV). Accuracy is ±10%; contact Kepco if greater
accuracy is required. There is no isolation between
±IMON, alarm circuit and d-c output. Refer to the applica-
ble RA 19-1U Manual for details.

ALARM CIRCUIT.  

The HSF-1UR includes an isolated

internal relay offering normally closed and normally open
contacts referenced to an isolated common. These con-
tacts may be used to configure “close on failure” or “open
on failure” alarm circuits. (Refer to the RA 19-1U Manual
for alarm configurations for multiple HSF-1UR power sup-
plies.)

KEYING. 

Keying of the HSF-1UR is established at the

factory (see Figure 2). The output voltage determines
which key pins are installed. When the proper holes in the
rack adapter are blocked by keying screws installed by the
user, only a power supply of the correct voltage can be
inserted in the rack adapter slot. (Refer to the RA 19-1U
Manual for rack adapter keying instructions.)

FIGURE 2.  REAR CONNECTOR PIN ASSIGNMENTS

PS2

PS1

3042496

PS4

PS3

Содержание HSF 3.3-25-1UR

Страница 1: ...exter nal connections are made through the rack adapter refer to the RA 19 1U manual which is available for free down load at www kepcopower com support opmanls htm ra19 1u Seven models may be selecte...

Страница 2: ...operate at less than maximum reducing stress and increasing reliability of the system If one unit fails the remaining units will continue to supply the load and the load current will be divided equal...

Страница 3: ...eering Remote sensing is recommended For master slave operation to work properly each unit should be adjusted to 40 mV optimum less than the next paral leled unit unit 1 is adjusted to VOUT unit 2 to...

Страница 4: ...20 ms min DIELECTRIC STRENGTH at 15 to 35 C ambient 10 to 85 relative humidity Between input and output 3KV a c for one minute cutout current 10ma Between input and ground 2KV a c for one minute cuto...

Страница 5: ...ERATURE 40o C to 75o C RELATIVE HUMIDITY Operating and storage 10 to 95 wet bulb temp 35o C non condensing FUSE Quick acting 5 0A 250V 5 2 x 20mm Littelfuse P N 215005PF Kepco P N 541 0134 DIMENSIONS...

Страница 6: ...CAUTION DO NOT repeatedly toggle the POWER on off switch as this may cause unit to fault When output voltage is available the VDC ON LED is on green For 100W and 150W 5V through 48V models the VDC ON...

Страница 7: ...ERS 5 TOLERANCES UNLESS OTHERWISE SPECIFIED 3 PLACES 0 005 2 PLACES 0 01 FRACTIONS 1 64 SEE DETAIL B 1 732 44 0 0 010 0 3 4 295 109 1 0 140 3 6 0 076 1 9 1 131 28 7 0 471 12 0 0 780 19 8 3 960 100 6 0...

Отзывы: