1-8
BOP 5-20DL 081915
1.4.3
OUTPUT ON-OFF PORT
The output of the unit can be turned ON (enabled) or turned OFF (disabled) from the rear panel
isolated ON-OFF Port. The pin configuration and requirements for the associated signals for the
Output ON-OFF port are described in Table 1-7. Output off signal value is adjustable (see PAR.
4.2.5):
to 0V ±0.001V by E
O
- OFF ZERO potentiometer in voltage mode
to 0A ±0.001A by I
O
- OFFZERO potentiometer in current mode.
NOTE: Contact Kepco if digital control of the model BOP 5-20DL power supply is desired.
Before installing any BIT card for digital control, the output ON/OFF feature must be
disabled. Once disabled, ON-OFF control is via the digital control card.
8
+
I
o Limit Input
Refer to PAR. 3.3.2
32
–Eo Limit Input
Refer to PAR. 3.3.4
34
–
I
o Limit Input
Refer to PAR. 3.3.2
10
Current Sensing Amp. Output
Analog output voltage (0 to ±10V, 1 mA max) proportional
to the prevailing BOP output current for remote metering
or monitoring.
20
Voltage Sensing Amp. Output
Analog output voltage (0 to ±10V, 1 mA max) proportional
to the prevailing BOP output voltage.
21, 43, 44,
45, 46
Not Used.
12, 14
Reserved.
(Not to be used).
16, 18
Current Mode Compensating Terminals
Refer to PAR. 1.4.4
26, 36
Turn-off Signal Output
Refer to PAR, 3.6.2
24
Circuit Breaker Control
Refer to PAR, 3.6.2
41
Non-isolated Turn-off Signal Input
Refer to PAR, 3.6.2
47/48,
49/50
Optically Isolated Turn-off Signal Input
Refer to PAR, 3.6.2
17
Voltage Comparison Amp Input
Analog input voltage of 0 to ±10V will produce 0 to ± full
output voltage.
19
Current Comparison Amp Input
Analog input voltage of 0 to ±10V will produce 0 to ± full
output current.
22
–10V Reference Voltage 4mA Max
Refer to PAR. 3.4.1 for examples.
28
+10V Reference Voltage 4mA Max
Refer to PAR. 3.4.1 for examples.
23, 25, 27,
29, 31, 33
Sensing Common
30
Reserved
(Not to be used).
35
Reserved
(Not to be used).
37
+5V
Built-in TTL Logic supply, 5V @ 40mA max.
38
I
o Limit Flag
Refer to PAR. 3.7
39
Eo Limit Flag
Refer to PAR. 3.7
40
Eo Mode Flag
Refer to PAR. 3.7
42
I
o Mode Flag
Refer to PAR. 3.7
TABLE 1-6. REAR PROGRAMMING CONNECTOR TERMINAL FUNCTIONS (CONTINUED)
TERMINAL
(Figure 3-1
FUNCTION
DESCRIPTION
Содержание BOP 5-20DL
Страница 2: ......
Страница 7: ......
Страница 8: ......
Страница 22: ......
Страница 23: ...081915 15 FIGURE 1 5 MECHANICAL OUTLINE DRAWING BOP 5 20DL ON OFF OUTPUT PORT ON OFF 1 15 1 16 Blank 14 15...
Страница 24: ......
Страница 31: ......
Страница 33: ...FIGURE 2 5 LOAD CONNECTION USING LOCAL SENSING AT REAR PANEL...
Страница 34: ......
Страница 47: ...instead of the front panel Voltage Programming Input terminals inverting...
Страница 64: ......
Страница 66: ......
Страница 70: ......