1-2
BOP 5-20DL 081915
TABLE 1-1. GENERAL SPECIFICATIONS
SPECIFICATION
RATING/DESCRIPTION
CONDITION/COMMENT
A-C Input Voltage
Nominal
104V / 115V / 208V / 230V
Internal setting, see Figure 2-3
Range
95-113V / 105-125V / 190-226V / 210-250V
Brown-out
93V / 103V / 186V / 206V
Frequency
50 / 60 Hz
nominal, ±3Hz range
A-C Input Current
11.0A
Nominal output power,
sourcing, @115V/ 60Hz
Active Input power
1050W
Nominal output power,
sourcing, @115V/ 60Hz
Power Factor
0.83
Nominal output power,
sourcing, @115V/ 60Hz
Input Leakage Current
(through earth-ground
connection)
0.1mA rms
115V/ 60Hz
Insulation Coordination
Input
Installation Cat. 2, Overvoltage Cat. 2,
Pollution Deg. 2
For TN or TT power systems
Output
Installation Cat. 2, Overvoltage Cat. 2,
Pollution Deg. 2
Max. 500V between COMMON
output terminal and chassis
Topology
Linear Half bridge (AB Class)
Mode of operation
Voltage Mode with
Current Limit and Voltage Limit
OR
Current Mode with
Voltage Limit and Current Limit
Mode of operation selectable
by front panel switch.
DC Transfer Factor
(Closed Loop Gain)
Voltage in
Voltage mode
-0.5V/V ±0.5%, with default preamplifier
For the default “inverting”
configuration.
Current in
Current mode
-2A/V ±0.1% with or without default pream-
plifier, after recalibration/readjustment
See Figures 3-9 and 3-18 for
“non-inverting” configurations in
voltage/current mode.
Preamplifier’s amplification
factor can be changed by
modifying connections and
adding resistors at rear
programming connector.
DC Transfer Factor is not
adjustable for voltage in voltage
mode nor for voltage and
current limits.
The DC Transfer Factor in
current mode is adjustable ±5%
by A3R316 (see PAR. 4.2.8).
Voltage in
Voltage limit
+0.55V/V ±2% for positive limit
-0.55V/V ±2% for negative limit
Current in
Current limit
+2.2A/V ±2% for positive limit
-2.2A/V ±2% for negative limit
Содержание BOP 5-20DL
Страница 2: ......
Страница 7: ......
Страница 8: ......
Страница 22: ......
Страница 23: ...081915 15 FIGURE 1 5 MECHANICAL OUTLINE DRAWING BOP 5 20DL ON OFF OUTPUT PORT ON OFF 1 15 1 16 Blank 14 15...
Страница 24: ......
Страница 31: ......
Страница 33: ...FIGURE 2 5 LOAD CONNECTION USING LOCAL SENSING AT REAR PANEL...
Страница 34: ......
Страница 47: ...instead of the front panel Voltage Programming Input terminals inverting...
Страница 64: ......
Страница 66: ......
Страница 70: ......