4
228-1917 REV 1
101719
KEPCO, INC.
131-38 SANFORD AVENUE
FLUSHING, NY. 11355 U.S.A.
TEL (718) 461-7000
FAX (718) 767-1102
www.kepcopower.com
email: [email protected]
3.5 SETUP BEFORE USE
Once the unit has been reassembled, the following procedure must be completed for the unit to function properly.
Refer to BOP-1KW (MG, ME, MGL, MEL) Operator’s Manual, P/N 243-1027 as needed.
1.
With POWER switch set to off position, connect the power supply to source power.
2.
With no load connected, set POWER switch to the ON position. Each time the unit is turned on an internal self-
test is performed. If all tests pass, the unit goes into the default mode. If a failure occurs, the failure is dis-
played.
3.5.1 SET LOAD TYPE TO INTERNAL.
Refer to CHANGING THE DEFAULT POWER UP SETTINGS paragraph of
the Operator Manual for further details.
1.
Press
%
from the power-up screen to enter the General Setup menu.
2.
Highlight Power-up Settings and press
!
.
3.
Highlight the Main Channel Reference and press
!
to modify. Use
Y
,
U
or the
ADJUST
control to highlight
INTERNAL, then press
$
to apply.
4.
Press
$
to save for power up.
3.5.2 CONFIGURE THE TRIGGER PORT.
Operation of the Trigger Port must be set from the front panel. Refer to
the USING THE TRIGGER PORT TO CUSTOMIZE OUTPUT ON/OFF OPERATION paragraph of the Operator
Manual for further details.
1.
Press
%
from the power-up screen to enter the General Setup menu.
2.
Highlight Load Type and press
!
to modify. Use
Y
,
U
or the
ADJUST
control to highlight the Remote On-
Off option, then press
!
to open the Output Configuration screen and show choices.
3.
Highlight either Disabled, High Is Off, Low Is Off, High Is On, Low Is On, or LowPulseOff, and press
$
to
save. Then press
$
to save for power-up,
3.5.3 RESET PASSWORDS.
Three passwords, Main Unit, Admin 1 and Admin 2, are used to protect operations
from the front panel when desired. These passwords must first be reset to their defaults. Refer to the PASSWORD
SETUP paragraph of the Operator Manual for further details.
1.
Press
%
from the power-up screen to enter the General Setup menu.
2.
Highlight Password and press
!
.
3.
Press
@
to reset passwords to the defaults: Admin 2 password is set to “
KEPCO
,” the Main Unit password is
set to ”
DEFAULT
,” and the Admin 1 password is not assigned.
4.
Press
$
to save for power up.
4. INSTRUCTION MANUAL CHANGES
BOP-1KW (EL, GL) Quick Start Guide, P/N 228-1699 is replaced by:
BOP-1KW (MG, ME, MGL, MEL) Quick Start Guide, P/N 228-1692
BOP-1KW (EL, GL) Operator Manual, P/N 243-1293 is replaced by:
BOP-1KW (MG, ME, MGL, MEL) Operator’s Manual, P/N 243-1027
Refer to the replacements listed above for complete instructions for the updated unit. These manuals can be
downloaded from the Kepco web site at