17
SUPERtrol-I LE Flow Computer
SELECT OPERATE STATE
Run
Setup
Test
SELECT EZ SETUP
CHANGES ALL SETUPS !
No
Yes
INSTRUMENT TYPE
Rate/Tot Batch
RATE TIME BASE
Sec Min Hour Day
RATE DEC PLACES(0-4)
0
TOTAL VOLUME UNITS
gal
TOT DEC PLACES (0-3)
0
K_FACTOR TYPE
Avg LinTbl
AVERAGE KA-FACTOR
####### P/gal
LINEAR TABLE KA
Fre01:######## Hz
LINEAR TABLE KA
KA--01:##########
FS ANALOG OUT 20mA
#######gal/m
RATE 00.0 gal/m
TOTAL 0 gal
6.2.1
TOP LEVEL
SETUP MENU
Menus
Display
Notes
Select Setup to enter the instrument setup routine.
Press ENTER to begin EZ Setup routine.
Confirm that you want to run EZ Setup. Caution: Any
previous program settings may be lost or reset.
Instrument Type.
Select the appropriate rate time base.
Enter the desired rate decimal location.
0-4 decimal places allowed.
Enter the desired totalizer units label.
Enter the desired totalizer decimal location. 0-3 decimal
places allowed.
Enter the desired K-Factor Type.
If Average selected, Enter the desired Average K-Factor.
If LinTbl selected,
Enter the desired frequency/ K-Factor pair for each point
in the Linearization Table.
Enter a frequency of 0 for any point other than Fre01 to
exit Linearization Table setup.
Enter the desired full scale setting for the analog output.
Return to Run Mode
6.2.2
EZ Setup
Sub-menu
Groups
6.2 EZ Setup
The EZ Setup routine is a quick and easy way to configure the unit for the most commonly used
instrument functions. This setup assumes that you are measuring Volumetric Flow using a high
level, DC Pulsing flow sensor. Entering the EZ Setup mode automatically sets many features. This
may cause any previously programmed information to be lost or reset. For a complete customized
configuration, see sections 6.3 and 6.4.
Through 16 Points