For future reference, please record the serial number of your
cooktop here:
STEP #2
Check the Electrical Supply Requirements
This product must be installed in accordance with national, state and local electric codes. The
following table provides the correct voltage, amperage and frequency that must be supplied to the
cooktop.
The supply must be from an individual grounded circuit that is protected by a circuit breaker and
rated per the specifications for the various models as shown in the table above.
Max Connected Required Power
Minimum
Kenyon Part # Model #
Load
Supply Input
Wire Size
B41540
Med2QTCP 2600 Watts
120VAC/22A/50/60Hz
#12 AWG
B41549
Med2QTCP 3000 Watts
208VAC/14.5A/50/60Hz
#12 AWG
B41541
Med2QTCP 3000 Watts
240VAC/12.5A/50/60Hz
#12 AWG
B41540L Med2QTCL 2600 Watts
120VAC/22A/50/60Hz
#12 AWG
B41549L
Med2QTCL 3000 Watts
208VAC/14.5A/50/60Hz
#12 AWG
B41541L
Med2QTCL 3000 Watts
240VAC/12.5A/50/60Hz
#12 AWG
B41575
Med2QTCTP 2400 Watts
120VAC/20A/50/60Hz
#12 AWG
B41579
Med2QTCTP 2400 Watts
208VAC/11.5A/50/60Hz
#12 AWG
B41576
Med2QTCTP 2400 Watts
240VAC/10A/50/60Hz
#12 AWG
B41575L
Med2QTCTL 2400 Watts
120VAC/20A/50/60Hz
#12 AWG
B41579L
Med2QTCTL 2400 Watts
208VAC/11.5A/50/60Hz
#12 AWG
B41576L
Med2QTCTL 2400 Watts
240VAC/10A/50/60Hz
#12 AWG
STEP #3
Countertop Preparation
Please read this section prior to making cutout for cooktop.
It is important to plan ahead for installation of the cooktop, keeping the following dimensions in
mind (please refer to Figure A).
Warning: If the electric power supply does not meet the product
specifications, consult with a licensed electrician before proceeding
with installation.
!
6