TS-590S
68
Service Jig
■
ACC 2 connector short plug
Use the same adjustment jig as the TS-570.
■
How to use the ACC 2 connector short plug
Insert the adjustment jig into the ACC 2 connector lo-
cated on the rear panel of the transceiver.
Adjustment Mode
■
Outline
1. You can adjust the transceiver in service adjustment
mode (adjustment using the panel keys) or with manual
adjustment (turning a coil and trimmer, etc). The service
adjustment mode (hereinafter referred to as “adjust-
ment mode”) has 63 items (Menu No. 00 to 62) and all
adjustment data is stored in the EEPROM (X53-446 A/3:
IC309).
2. You can enter adjustment mode and change each setting
data.
3. New data is written to the EEPROM by performing
Menu No. 60 writing.
■
Operation procedures in adjustment mode
1. How to start the adjustment mode
• Insert the adjustment jig into the ACC 2 connector lo-
cated on the rear panel of the transceiver.
• Turn the transceiver ON while pressing the [MIC] key
and [NR] key, to enter adjustment mode and the Menu
No. appears on the Memory channel number display.
Remove the adjustment jig from the transceiver when
the Menu No. appears.
Menu No.
2. Select the adjustment mode Menu No.
Turn the [MULTI/CH] knob to change the Menu No.
3. Change the adjustment mode setting data
Setting data can be changed using the [
] or [
] key.
4. Write the adjustment mode data
Press the [
] or [
] key on the main unit or the [UP] or
[DWN] key on the microphone on Menu No. 60.
5. Cancel the adjustment mode
Press the [CLR] key to return to normal VFO mode.
Note:
When the power is turned OFF during the adjustment
mode, adjustment mode is canceled.
■
Adjustment Mode Menu (Menu No. 00~62)
No.
Adjustment
Item
Display
Condition
Frequency
(MHz)
RX IF
(MHz)
Mode
00
CAR Point
10M 2.7k
1.81
73
USB
01
11M 2.7k
1.81
11
USB
02
11M 500H
1.81
11
CW
03
HF 11M IF Gain
HF11 GAIN
14.2
11
USB
04
HF 73M IF Gain
HF73 GAIN
14.2
73
USB
05
11M Mix BAL
HF11 BAL
0.136
11
USB
06
73M Mix BAL
HF73 BAL
0.100
73
USB
07
AGC Reference
AGC REF
14.2
73
USB
08
HF S-Meter
HF.SSB S1
14.2
11
USB
09
HF.SSB S9
10
HF.SSB SF
11
HF FM S-Meter
HF.FM. S1
29.2
73
FM
12
HF.FM.SFUL
13
HF FM Squelch
HF.FM.SQ.TH
29.2
73
FM
14
HF.FM.SQ.TI
15
50M IF Gain
50. GAIN
50.2
73
USB
16
50M S-Meter
50.SSB S1
50.2
73
USB
17
50.SSB S9
18
50.SSB SF
19
50M FM S-Meter
50.FM S1
50.2
73
FM
20
50.FMSFUL
21
50M FM Squelch
50.FM.SQ.TH
50.2
73
FM
22
50.FM.SQ.TI
23
ALC Reference
ALC REF
14.1
73
USB
24
POC/
Power Meter
POC 100W
14.1
73
CW
25
P.MTR 100W
14.1
26
50M 100W
50.1
ADJUSTMENT
Содержание TS-590S