TS-590S
67
Updating the Firmware
The fi rmware of the main MCU and DSP can be updated
using the “TS-590 Update” update software. Update the
firmware according to the procedure displayed in update
software.
Refer to the help file of the update software for a de-
tailed procedure.
Download the latest “TS-590 Update” update software
from the following URL:
http://www.kenwood.com/i/products/info/amateur/
software_download.html
* The URL may change without notice.
Note:
Update the fi rmware after replacing the main MCU or
Flash memory.
Required Test Equipment
1. DC Voltmeter (DC V.M)
1) Input resistance: More than 1M
Ω
2) Voltage range: 1.5 to 1000V AC/DC
Note:
A high-recision multimeter may be used. However,
accurate readings can not be obtained for high- impedance
circuits.
2. DC Ammeter
1) Current range: 100mA, 1.5A, 30A, high-precision amme-
ter may be used.
3. RF VTVM (RF V.M)
1) Input impedance: 1M
Ω
and less than 3pF, min.
2) Voltage range: 10mV to 300V
3) Frequency range: 10kHz to 500MHz
4. AF Voltmeter (AF V.M)
1) Frequency range: 50Hz to 10kHz
2) Input resistance: 1M
Ω
or greater
3) Voltage range: 10mV to 30V
5. AF Generator (AG)
1) Frequency range: 200Hz to 5kHz
2) Output: 1mV or less to 1V, low distortion
6. AF Dummy Load (DM. SP)
1) Impedance: 8
Ω
2) Dissipation: 3W or greater
7. Oscilloscope
Requires high sensitivity, and external synchronization
capability (150MHz or greater).
8. Standard Signal Generator (SSG)
1) Frequency range: 50kHz to 60MHz
2) Output: –133dBm/0.1µV to 7dBm/1V
3) Output impedance: 50
Ω
4) AM and FM modulation can be possible
Note:
Generator must be frequency stable.
9. Frequency Counter (f. counter)
1) Minimum input voltage: 50mV
2) Frequency range: 150MHz or greater
10. Noise Generator (Noise G.)
Must generate ignition noise containing harmonics be-
yond 60MHz.
11. Audio Analyzer
12. RF Dummy Load
1) Impedance: 150
Ω
and 50
Ω
2) Dissipation: 150W or greater
13. Linear Detector
1) Frequency range: 60MHz or greater
14. Power Meter
1) Impedance: 50
Ω
2) Dissipation: 300W continuous or greater
3) Frequency limits: 60MHz or greater
15. Spectrum Analyzer
1) Frequency range: 100kHz to 140MHz or greater
2) Bandwidth: 1kHz to 3MHz
16. Tracking Generator
17. Directional Coupler
18. Monitor Receiver
19. Microphone
MC-43S or MC-60S8
20. Distortion Meter
21. Double Signal Pad (50
Ω
)
Preparation
Unless otherwise specifi ed, knobs and switches should
be set as follows.
POWER
..................................................................ON
NOTCH
............................................................. Center
AF
......................................................................... MIN
RF
........................................................................ MAX
SQL
...................................................................... MIN
■
Front panel
■
Rear panel
ADJUSTMENT