Field Programming Reference (FPRG)
54
6 EDIT MENU
6.11 Multi-table Window
It can configure the QT/DQT (Current) code on this
window. When the Multi-table function is enabled, it can
wait for the call with two types of QT/DQT code; Primary
and Current.
(Refer to 6.1.6 Multi-table, 6.2.9 Multi-table
This window consists of “Main-table” and “Sub-table” tabs
and it can switch the window by clicking the tabs.
6.11.1 Decode (Multi-table)
It can configure the signalling used to receive the calls.
Select the QT tone or DQT code from the dropdown list or
directly enter the QT tone and the DQT code.
#
Selecting the QT/DQT Encode Code from the
Dropdown List:
#
Directly entering the QT/DQT Encode Code:
Note:
!
It cannot configure the QT/DQT code to the No.1 table.
!
It can use numbers, “D”, “N”, “I”, “.”, and “,” for the 5 digits of the
QT/DQT Encode code.
!
When entering only numbers, the code is configured as QT
Tone.
!
When entering “D” as the first character of the code, the code is
configured as the DQT code.
!
When entering the value, which is out of the range, it will be
automatically replaced with the highest value or the lowest value
in the range.
6.11.2 Encode (Multi-table)
It can configure the signalling used to transmit.
Select the QT tone or DQT code with the dropdown list or
directly enter the QT tone and the DQT code.
#
When Selecting the QT/DQT Encode Code with the
Dropdown List:
#
Directly entering the QT/DQT Encode Code:
Note:
!
It cannot configure “Encode” if the “Decode” function is not
configured.
!
It can use numbers, “D”, “N”, “I”, “.”, and “,” for the 5 digits of the
QT/DQT Encode code.
!
When entering only numbers, the code is configured as QT
Tone.
!
When entering “D” as the first character of the code, the code is
configured as the DQT code.
!
When entering the value, which is out of the range, it will be
automatically replaced with the highest value or the lowest value
in the range.
Range
QT
67.0 - 250.3 Hz
DQT Normal
D023N - D754N
DQT Inverse
D023I - D754I
Default
None
Range
QT
67.0 - 254.1 Hz
DQT Normal
D000N - D777N
DQT Inverse
D000I - D777I
In steps of
QT
0.1 Hz
DQT
1
Default
None
Range
QT
67.0 - 250.3 Hz
DQT Normal
D023N - D754N
DQT Inverse
D023I - D754I
Default
None
Range
QT
67.0 - 254.1 Hz
DQT Normal
D000N - D777N
DQT Inverse
D000I - D777I
In steps of
QT
0.1 Hz
DQT
1
Default
None