6 EDIT MENU
49
Field Programming Reference (FPRG)
6.10.2 AUX Tab
It can configure functions assigned to the AUX Input port,
AUX Output port, and the AUX Input/Output port in this
tab.
Figure 6-20 AUX tab
"
AUX Input Trigger (AUX Input)
This is a method to detect the signal applied to the
Auxiliary Input ports Select “Level” or “Down Edge”
from the dropdown list.
Note:
Although TKR-750/850/751/851 performs the detection
when the detection is enabled, it performs Start Up first
when Start Up is enabled when the “Level” is selected.
(Refer to 6.4.3 Others Tab (Optional Features).)
"
1st, 2nd, 3rd (AUX Input)
You can assign three functions (1st, 2nd, and 3rd) to
the AUX Input port and the AUX Input/Output port.
Select the functions from the dropdown list.
Note:
!
As for the AUX Input/Output port, it appears on the list only
when it is configured as the “AUX Input” port in the “AUX
Select” tab.
(Refer to 6.10.1 AUX Select Tab.)
!
It cannot configure any functions to “2nd” and “3rd” when
“1st” is configured as “None”, and it cannot configure any
functions to “3rd” when “2nd” is configured to “None”.
Table 6-6 Assigning Functions to the Auxiliary Input Ports
(Functions in GLAY are available only
when Down Edge is detected.)
Range
Level
Perform the trigger detection when the
port is in Active Low.
Down Edge
Perform the trigger detection with
Down Edge on the input signal.
Default
Level
Range
Refer to Table 6-6 Assigning Functions to the
Auxiliary Input Ports.
Default
1st: None
2nd: Cannot be configured.
3rd: Cannot be configured.
Function Name
Description
None
Not perform any operation.
AUX Out 1 Off
-
AUX Out 5 Off
When the signal is applied to one of the PF [AUX Out 1 Off] - PF [AUX Out 5 Off] input ports, the function
assigned to the Auxiliary Output port is deactivated.
You can assign this function when “Selectable” is configure to the Auxiliary Output ports 1 to 5.
6-7 Assigning Functions to the Auxiliary Output Ports.)
AUX I/O 1 Off
-
AUX I/O 6 Off
When the signal is applied to one of the PF [AUX Out 1 Off] - PF [AUX Out 6 Off] input ports, the function
assigned to the Auxiliary I/O port is deactivated.
You can assign the function when “Selectable” is configured to the Auxiliary I/O ports 1 to 6.
Assigning Functions to the Auxiliary Output Ports.)
AUX Out 1 On
-
AUX Out 5 On
When the signal is applied to one of the PF [AUX Out 1 On] - PF [AUX Out 5 On] input ports, the function
assigned to the Auxiliary Output port is activated.
You can assign this function when “Selectable” is configure to the Auxiliary Output ports 1 to 5.
6-7 Assigning Functions to the Auxiliary Output Ports.)
AUX I/O 1 On
-
AUX I/O 6 On
When the signal is applied to one of the PF [AUX I/O 1 On] - PF [AUX I/O 6 On] input ports, the function
assigned to the Auxiliary I/O port is disabled.
You can assign the function when “Selectable” is configured to the Auxiliary I/O ports 1 to 6.
Assigning Functions to the Auxiliary Output Ports.)
AUX Out 1 On/Off
-
AUX Out 5 On/Off
Switch enable/disable the function assigned to the Auxiliary Output port when the signal is applied to one of the
PF [AUX Out 1 On/Off] to PF [AUX Out 5 On/Off] input ports.
You can assign this function when “Selectable” is configure to the Auxiliary Output ports 1 to 5.