TK-90
78
Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
ADJUSTMENT
3. IF gain
1) Menu No. : 2
SSG
Rear
ANT
[
] or Check the adjust-
(13.2MHz, USB)
panel
[
]
ment value (A)
SSG f. : 13.201MHz
Oscilloscope
EXT.SP
displayed on the left
SSG output : OFF
AF V.M
side of the display.
DM. SP
2) SSG output : –107dBm (1.0
µ
V)
Change the adjust-
ment value (B)
displayed on the
right side of the
display by pressing
the [
] or [
]
keys so that adjust-
ment value (A)
increace by 5 (A+5).
4. S/N
1) Display f. : 550kHz
SSG
Rear
ANT
• 550kHz
Mode : AM
panel
PRE-AMP : ON
Oscilloscope
EXT.SP
*AF output : 0.45V/4
Ω
(LV7)
AF V.M
SSG f. : 550kHz
Distortion
SSG output : –79dBm (25
µ
V)
meter
MOD : 1kHz, 60%
DM. SP
Audio
2) MOD : OFF
analyzer
Check
–10dB or less
• 13.2MHz
3) Display f. : 14.200MHz
Mode : DATA
PRE-AMP : ON
*AF output : 0.45V/4
Ω
(LV7)
SSG f. : 13.201MHz
SSG output : –121dBm (0.2
µ
V)
4) SSG output : OFF
Check
–10dB or less
• PRE-AMP
5) Display f. : 13.200MHz
Set SINAD at 0dB.
gain
Mode : DATA
PRE-AMP : ON
*AF output : 0.45V/4
Ω
(LV7)
SSG f. : 13.201MHz
SSG output : –118dBm (0.28
µ
V)
6) PRE-AMP : OFF
Check
–(5~15)dB
• RF ATT
7) Display f. : 13.200MHz
AF level = A
Mode : DATA
ATT : OFF
*AF output : 0.2V/4
Ω
SSG f. : 13.201MHz
SSG output : –116dBm (0.35
µ
V)
8) ATT : ON
Check for AF level
A
±
2dB
SSG output : –96dBm (3.54
µ
V)
*: When the volume cannot be decreased, verify the value set for “Minimum Volume”.
When “Minimum Volume Type” is set to “Lowest Limit” in the FPU, the volume cannot be decreased lower than the value set for the “Minimum Volume”.
M 2
I F G : 0 4 8 0 3 3
A
M 2
I F G : 0 5 3 0 3 3
A+5
B