TK-8302/8302H
28
Test Equipment Required for Alignment
Test Equipment
Major Specifi cations
1.
Standard Signal Generator (SSG)
Frequency Range
400 to 520MHz
Modulation
Frequency modulation and external modulation
Output
–127dBm/0.1µV to greater than –7dBm/100mV
2. Power
Meter
Input Impedance
50
Ω
Operation Frequency
400 to 520MHz or more
Measurement Range
Vicinity of 100W
3.
Deviation Meter
Frequency Range
400 to 520MHz
4.
Digital Volt Meter (DVM)
Measuring Range
1 to 20V DC
Input Impedance
High input impedance for minimum circuit loading
5.
Oscilloscope
DC through 30MHz
6. High
Sensitivity
Frequency
Counter
Frequency Range
10Hz to 1000MHz
Frequency Stability
0.2ppm or less
7.
Ammeter
20A or more
8.
AF Volt Meter (AF VTVM)
Frequency Range
50Hz to 10kHz
Voltage Range
1mV to 3V
9.
Audio Generator (AG)
Frequency Range
20Hz to 20kHz or more
Output
0 to 1V
10. Distortion
Meter
Capability
3% or less at 1kHz
Input Level
50mV to 10Vrms
11. 4
Ω
Dummy Load
Approx. 4
Ω
, 10W or more
12. Regulated Power Supply
13.6V, approx. 20A (adjustable from 9 to 17V)
Useful if ammeter equipped
13. Spectrum Analyzer
Center Frequency
50kHz to 600MHz
14. Tracking Generator
Output Voltage
100mV or more
MIC connector (Front panel view)
Test cable for microphone input (E30-3360-28)
Tuning cable (E30-3383-05)
Adapter cable (E30-3383-05) is required for inject-
ing an audio if PC tuning is used.
See “PC Mode” section for the connection.
3
2
4
5
6
7
8
3
1
2
4
5
6
7
8
1
GREEN
RED
BLACK
BLUE
SHIELD
WHITE
GRAY
YELLOW
PTT
E
MIC-E
MIC
HK
Lead wire +
MIC
Shield wire –
1 : MBL
2 : SB
3 : GND
4 : PTT
5 : ME
6 : MIC
7 : HOOK
8 : DM
ADJUSTMENT
1
8