TK-8180/8189
17
■
Top packing installation procedure
1. Place the top packing over the shielding plate.
2. Fit the convex tab of the top packing into the hollow of the
chassis. (
q
)
3. Fit the chassis into the groove of the top packing. (
w
)
Verify that the top packing is in close contact with the
chassis.
q
w
■
FINAL shield case (F10-3032-04) installation
procedure
1. Place the shield case on the final section of the TX-RX unit
(B/3).
2. The shield case is installed on the positioning boss of the
chassis by pushing down on “PUSH2” (on the shield case)
while pushing “PUSH1” (stamped on two parts on the
shield case) to the right.
■
Power supply cable installation procedure
1. Pass the power supply cable through the chassis hole
(
q
) as shown in Figure 5-1 and insert the bush into the
chassis hole.
2. Rotate the bush of the power supply cable 90 degrees
clockwise as viewed from the rear of the chassis. (
w
)
3. Align the ignition sense connector (yellow) of the power
supply cable around the chemical capacitor (C801) and
connect it to the TX-RX unit (B/3) connector (CN804).
4. Align the + (positive) terminal of the power supply cable
(red) as shown in Figure 5-2 and fix it to the terminal strip
with a screw.
5. Align the – (negative) terminal of the power supply cable
(black) as shown in Figure 5-2 and fix it to the terminal strip
with a screw.
IC417
CN804
Black
Red
C801
w
q
Fig. 5-1
Fig. 5-2
Fig. 6
DISASSEMBLY FOR REPAIR
■
D-sub cap installation procedure
To improve water resistance, fit the D-sub cap into the D-
sub terminal hardware fixture of the transceiver in the follow-
ing order:
1. Fit the left side (
q
) of the D-sub cap into the hardware
fixture.
2. Fit the right side (
w
) of the D-sub cap into the hardware
fixture.
3. Fit the center (
e
) of the D-sub cap into the hardware fix-
ture.
Verify that the D-sub cap is in close contact with the hard-
ware fixture.
q
w
e
Fig. 7