4-1. Adding the data password.
If the Read Authorization password is set in the optional
feature menu, you must enter the password (Master trans-
ceiver) to activate a clone mode.
You can use 0~9 to configure the password. The maxi-
mum length of the password is 6 digits.
1. [
]+Power ON.
2. “CLN LOCK” (TK-8160) or “P” (TK-8162) is displayed on
the LCD.
3. If the [
] and [
] keys is pressed while “CLN LOCK”
(TK-8160) or “P” (TK-8162) is displayed, numbers (0 to 9)
are displayed flashing. When you press the [
] key, the
currently selected number is determined. If you press the
[
] key after entering the password in this procedure,
“CLONE” (TK-8160) or “C” (TK-8162) is displayed if the
entered password is correct. If the password is incorrect,
“CLN LOCK” (TK-8160) or “P” (TK-8162) is redisplayed.
Clone cable
(E30-3382-05)
Fig, 2
■
Flow Chart (Master radio)
Press [ ] key+Power ON for 2 seconds
Is
password*
set?
Yes
No
Shows CLN LOCK or C
Input password if
password is correct
Clone mode
[ ]
Start the clone function
* Read
Authorization
password
5. Self Programming Mode
Self programming mode operates with only the
TK-8160
transceiver.
Write mode for frequency data and signaling, etc. To be
used ONLY by the authorized service person maintaining the
user’s equipment. After programming, reset the FPU to the
“Self- Programming” disabled mode. Radios CANNOT be
delivered to the end-user in the self-programming mode.
5-1. Enter to the Self Programming Mode
Hold down the [
] key 2 seconds and turn the power
switch on. When enter the self programming mode, “1- 1”
is displayed 2 seconds after “ SELF ” is displayed.
5-2. Adding the Data Password
If the data password is set in the optional feature menu,
you must enter the password to activate a self programming
mode.
You can use 0~9 to configure the password. The maxi-
mum length of the password is 6 digits.
1. [
]+Power ON.
2. “SLF.LOCK.R”* is displayed on the LCD.
3. If the [
] and [
] keys is pressed while “SLF.LOCK.R”
is displayed, numbers (0 to 9) are displayed flashing.
When you press the [
] key, the currently selected
number is determined. If you press the [
] key after en-
tering the password in this procedure, “SELF” is dis-
played if the entered password is correct. If the password
is incorrect, “SLF.LOCK.R”* is redisplayed.
* Read authorization password
→
“SLF.LOCK.R”
Overwrite password
→
“SLF.LOCK.W”
Note :
This mode (self programming mode) cannot be set when
it has been disabled with the FPU.
5-3. Channel Setting Mode
Each channel can be setup in its action mode by using the
panel keys.
The 5-tone functions cannot be programmed in this mode.
• Pressing [
] when “1- 1” is displayed, sets channel
setting mode.
• Select an item set using [
] then change the selection
with the [
] or [
].
• The data displayed using [
] is stored in the memory.
• Pressing [
] proceeds to the next item without storing it
in the memory.
• Press [
] to set the display to “ SELF ” and return to
reset (default) status.