![Kenwood TK-8160 Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/kenwood/tk-8160/tk-8160_service-manual_191541055.webp)
TK-8160/8162
50
LEVEL DIAGRAM
To make measuremen
G2
Q351
1
IC211
IC241
Q353
XF351
1
IC213
IC241
BPF
BPF
2
Q406
ANT
X54-351 or
X54-352
G2
To make measurements in the RF section, connect the RF level meter.
In the RF section, use a 0.01
µ
F coupling capacitor.
(The display shows the SSG input value required to obtain 12dB SINA
Q446
21
G1
20
S
Q352
10
Display
Unit
D
IC201
TX-RX Unit (VCO)
MIC
To make measurements in the AF section, connect the AC level meter.
AG is set so that MIC input becomes 3kHz/1.5kHz (Wide/Narrow) DEV at 1kHz MOD.
D
CF331
/CF332
450kHz
6
TX-RX Unit
S
IC321
2
49.95MHz
9
G1
20
2
Center Frequency
–2.0dBm
W : –120.5dBm
N : –120.0dBm
W : –121.0dBm
N : –121.0dBm
W : –108.0dBm
N : –107.0dBm
W : –111.5dBm
N : –110.5dBm
W : 0.49Vrms
N : 0.26Vrms
W : –111.0dBm
N : –110.5dBm
W : –100.0dBm
N : –98.0dBm
W : –79.0dBm
N : –76.5dBm
W/N
5.0mVrms
W/N
0.18Vrms
W/N
0.20Vrms
W/N
0.30Vrms
W/N
0.80Vrms
Receiver Section
Transmitter Section