TK-8108H
31
ADJUSTMENT
PCB Section
1. Setting
1) Power supply voltage
DC Power supply terminal : 13.6V
2. VCO lock
1) CH : TX high
Digital voltmeter
CV
TC402
5.5V
±
0.1V
voltage*
2) CH : RX high
TC401
5.5V
±
0.1V
3) CH : TX low
Check
0.7V or more
4) CH : RX low
3. IF coil
1) CH : RX center (Wide)
SSG
AFV
L301
3.25~3.35V (DC)
2) SSG output : –53dBm (501
µ
V)
Digital voltmeter
Mod : 1kHz
Dev : 3kHz
4. RF
1) CH : RX center (Wide)
Tra generator
ANT
TC352
Adjust the BPF waveform
bandpass
CH : RX low (Wide)
Spectrum analyzer
BPF
TC353
to Fig. 1
filter
CH : RX high (Wide)
2) Tra generator output : –30dBm
Connect the spectrum analyzer
to BPF terminal
* Adjustment of TX VCO lock voltage
1. Remove R525, R823, R536 and R822 (all on component side).
2. Remove PCB from chassis.
3. Transmit and check voltage at [CV] point.
Warning :
Do not transmit if step “1.” is not complete.
4. Adjust of voltage can be done by tuning TC402.
Item
Condition
Test equipment
Terminal
Parts
Method
Specifications/
Remarks
Measurement
Adjustment
Fig. 1
Test Frequency (MHz)
Channel
TX
RX
1 : Center
470.100
470.050
2 : Low
450.100
450.050
3 : High
489.900
489.950
4
470.000
470.000
5
470.200
470.200
6
470.400
470.400