51
ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-760G/
(
N
)
/762G/
(
N
)
6. QT check
1) Set test mode
SSG
Rear
ANT
CH : CH1 - Sig4
panel
SSG MOD
AF VTVM
ACC
INT : 3kHz (Wide), 1.5kHz (Narrow) Distortion
(EXT.SP)
EXT : 151.4Hz
meter
SSG system MOD DEV
Oscilloscope
:
±
3.75kHz (Wide),
±
1.85kHz (Narrow) AG
SSG output : 10dB SINAD level
2) CH : CH1 - Sig3
Check
Squelch must be opened.
CH1 - Sig5
CH1 - Sig6
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
1. Frequency
1) Set test mode
Power meter Rear
ANT
Front
CH
/
Check
160.100MHz
±
50Hz
Select “FREQ” in tuning mode. F. counter panel
panel
PTT : ON
Adjust [_**]
2. Power
1) Maximum power
Check
More than 26.0W
output
Set test mode
Select “HPOW” in tuning mode.
“H
.
POW”
Adjust [256]
PTT : ON
3. High power
1) Set test mode
25.0W
±
1.0W
Select "HPOW" in tuning mode.
“H
.
POW”
PTT : ON
Adjust [***]
2) “H
.
P
.
OW”
PTT : ON
Adjust [***]
3) “H
.
P
.
O
.
W”
PTT : ON
Adjust [***]
4) “H
.
P
.
O
.
W
.
”
PTT : ON
Adjust [***]
5) “H
.
P
.
O
.
W
.
_
.
”
PTT : ON
Adjust [***]
4. Low power
1) Set test mode
Power meter
6.0W
±
0.5W
Select “LPOW” in tuning mode.
“L
.
POW”
PTT : ON
Adjust [***]
2) “L
.
P
.
OW”
PTT : ON
Adjust [***]
Transmitter Section