TK-372G
42
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark
K2 type
1. BPF
(PANEL TEST MODE)
Tracking generator
ANT
TC301, TC302,
Adjust wave form to figure 1.
Adjustment CH-Sig 1-1
Spectrum analyzer
BPF
TC303
Tra-G setting -40dBm
2. Sensitivity
[Panel Test Mode]
SSG
ANT
Check
1) CH-Sig:1-1
AF VTVM
Check
12dB SINAD or
SSG OUT
Oscilloscope
more
Wide:-118dBm (0.28
µ
V)
(MOD:1kHz /
±
3kHz)
Narrow:-116dBm (0.35
µ
V)
(MOD:1kHz /
±
1.5kHz)
3. Squelch (Open) 1) Adj item [SQL3]
Encoder
Adjust to the
Adjust
Adjust [
∗∗∗
]
knob
squelch
[Wide]
SSG OUT:
squelch.
threshold point
-124dBm
2) Adj item [SQL3.]
Adjust [
∗∗∗
]
SSG OUT:
[Narrow]
-123dBm
4. Squelch(Tight) 1) Adj item [SQL9]
Adjust to the
Adjust
Adjust [
∗∗∗
]
squelch
[Wide]
SSG OUT:-116dBm (0.35
µ
V)
threshold point
[Narrow]
2) Adj item [SQL9.]
SSG OUT:-115dBm (0.4
µ
V)
5. Squelch
[Panel Test Mode]
Check
Squelch must
Check
1) CH-Sig:1-1
be opened.
SQ Level : [SQL5]
SSG OUT:
-118dBm (0.28
µ
V)
2) SSG OUT:OFF
Squelch must
be closed.