TK-372G
37
Common Section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark
1. Setting
1) BATT terminal voltage:7.5V
2) SSG Standard modulation
[Wide] MOD:1kHz, DEV:3kHz
[Narrow] MOD:1kHz, DEV:1.5kHz
[Semi wide]
MOD:1kHz, DEV:2.4kHz
2. VCO lock
[Panel Test Mode]
voltage
1) CH-Sig:2-1
Power meter
ANT
Check
0.8V or more
RX
2) CH-Sig:3-1
DVM
CV(LV)
4.0V
±
0.1V (K)
4.0V
±
0.1V (K4)
4.1V
±
0.1V (K2)
TX
3) CH-Sig:2-1
0.8V or more
PTT:ON
4) CH-Sig:3-1
4.0V
±
0.1V (K,
PTT:ON
K2, K3)
3.5V
±
0.1V (K4)
Transmitter Section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark
1. Frequency
1) PTT:ON
Freq. Counter
ANT
VR1
Center frequency
Adjust
Power meter
(460.0 MHz)
±
100Hz (K)
Am meter
(416.5 MHz)
±
100Hz (K4)
(480.0 MHz)
±
100Hz (K2)
(501.0 MHz)
±
100Hz (K3)
2. Max Power 1) Adj item [HPOW]
Check
4.2W or more
Check
Adjust [256]
2) Adj item
[H
.
P O W]
➞
[H
.
P
.
O W]
➞
[H
.
P
.
O
.
W]
➞
[H
.
P
.
O
.
W
.
]
➞
[H
.
P
.
O
.
W
.
.
]
Adjust [256]
PTT:ON
3. Hight Power 1) Adj item [HPOW]
Encoder
4.2W
±
0.1W
Adjust
Adjust [
∗∗∗
]
knob
2.2A or less
2) Adj item
[H
.
P O W]
➞
[H
.
P
.
O W]
➞
[H
.
P
.
O
.
W]
➞
[H
.
P
.
O
.
W
.
]
➞
[H
.
P
.
O
.
W
.
.
]
Adjust [
∗∗∗
]
PTT:ON
4. Hight Power [Panel Test Mode]
Check
1) CH-Sig:1-1
Check
3.0~5.0W
PTT:ON
2.3A or less
2) CH-Sig:2-1
PTT:ON
3) CH-Sig:3-1
PTT:ON
5. Low Power 1) Adj item [LPOW]
Encoder
1.0W
±
0.1W
Adjust
Adjust [
∗∗∗
]
knob
1.0A or less
2) Adj item
[L
.
P O W]
➞
[L
.
P
.
O W]
➞
[L
.
P
.
O
.
W]
➞
[L
.
P
.
O
.
W
.
]
➞
[L
.
P
.
O
.
W
.
.
]
Adjust [
∗∗∗
]
PTT:ON
Note
Precision parts are used for the PTT, side1, and side2 switches.
In order to avoid damaging these switches, do not press them using your fingers. However, if it is necessary to press these
switches, be sure to press them at 90˚ angles, pressing them at other angles can easily damage the parts.
ADJUSTMENT