16
TK-3118
TK-260
:K, K2
Use the KPG-69D programming software for adjustment of the next item in PC MODE (see page 10).
Squelch Level, S meter Level, Lo Power, Hi Power, QT Deviation, DQT Deviation, and Battery warning.
ADJUSTMENT
Parts
TC1
TC2
Method
1.0V (C,C4)
1.0V (C,C4)
Specifications/
Remarks
±
0.1V
±
0.1V
less than 4.5V
Terminal
CV
Test equipment
Digital voltmeter
Condition
1) Power supply voltage
Battery teriminal:7.5V
1) CH: TX low
2) CH: RX low
3) CH: TX high
4) CH: RX high
Section common to the transmitter and receiver (VCO)
Item
1. Setting
2. VCO lock
voltage
Measurement
Adjustment
Parts
TC3,TC5
L22
PC key
PC key
Method
Adjust the spectram waveform
shown Fig1
Adjust to the MAX AF level
Vol. knob position at 12 o'clock
Check
Adjust to open the squelch.
Adjust to open the squelch.
Adjust to Full digit
Adjust to one digit
Specifications/
Remarks
SINAD: 12dB or
higher
Terminal
ANT
SP
ANT
Test equipment
Tra generator
Spectrum analyzer
SSG
Oscilloscope
AF. V. M
Distortion meter
SSG
Condition
1) CH: RX center
1) CH: RX center
SSG output: -53dBm(501
µ
V)
MOD: 1kHz
DEV:
±
3.0kHz
1) CH: RX center
CH: low
CH: high
SSG ouput: -116dBm(0.35
µ
V)
MOD: 1kHz
DEV:
±
3.0kHz
1) CH: RX center
2) Level 9
SSG output: -116dBm(0.35
µ
V)
3) Level 1
SSG output: -123dBm(0.16
µ
V)
1) CH: RX center
2) Full digit
SSG output: -110dBm(0.7
µ
V)
3) one Digit
SSG output: -120dBm(0.2
µ
V)
Receiver Section
Item
1. Band-
pass filter
2. AF level
3. Sensitivity
4. Squelch
Level
(PC Mode)
5. S meter
Level
(PC Mode)
Measurement
Adjustment
Transmitter section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark
1. Transmit
1) CH: TX center
Frequency
ANT
VR1
Adjust to center frequency
within
±
100Hz
frequency
PTT: ON
counter
2. DQT/QT
1) CH: TX center
Modulation analyzer
VR301
Rectify the waveform to square
Balance
wave
3. Lo Power
1) CH: TX center
Power meter
PC key
Adjust it to 2W
within
±
0.1W
(PC Mode)
CH: TX low
Current meter
CH: TX high
4. Hi Power
1) CH: TX center
Power meter
PC key
Adjust it to 5W
within
±
0.2W
(PC Mode)
CH: TX low
Current meter
CH: TX high
5. MAX DEV 1) CH: TX center
Modulation
VR302
Adjust it to
±
4.2kHz (Wide)
±
100Hz
AG: 1kHz/50mV
analyzer 15kHz LPF
AG, AF. V. M
Check (Narrow)
±
1.9kHz~2.2kHz
6. MIC
1) CH: TX center
Check (Wide)
±
2.2kHz~3.8kHz
Sensitivity
AG: 1kHz/5mV
7. QT
1) CH: TX center
Modulation
PC key
Adjust it to 0.75kHz (Wide)
±
0.05Hz
Deviation
CH: TX low
analyzer 3kHz LPF
Adjust it to
±
0.35kHz (Narrow) (Wide/Narrow)
(PC Mode)
CH: TX high
CH: TX Center
QT: 151.4Hz
8. DQT
1) CH: TX center
Modulation
PC key
Adjust it to
±
0.75kHz (Wide)
±
0.05Hz
Deviation
CH: TX low
analyzer 3kHz LPF
Adjust it to
±
0.35kHz (Narrow) (Wide/Narrow)
(PC Mode)
CH: TX high
CH: TX Center
DQT:023N
9. DTMF
1) CH TX center using [9] key
Modulation
VR303
Adjust it to 2.5kHz (Wide)
±
100Hz
Deviation
analyzer 15kH LPF
10.VOX Level
PC key
Adjust it to [4]
(PC Mode)
11.Battery
1) Battery terminal: 5.5V
PC key
Warning
(PC Mode)