TK-2402(V)/2402/2406/2407
29
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
2. Open
Squelch
[Wide]
1) TEST CH: Low, Center, High
(3
points)
2) SSG otuput: –120dBm
SSG MOD: 3.0kHz
AF Freq : 1kHz
SSG
DVM
Oscilloscope
ANT
FPU
Press [Start]
(Auto tuning)
[Narrow]
1) TEST CH: Low, Center, High
(3
points)
2) SSG otuput: –119dBm
AF Freq : 1kHz
SSG MOD: 1.5kHz
3. Tight
Squelch
[Wide]
1) TEST CH: Low, Center, High
(3
points)
2) SSG otuput: –115dBm
AF Freq : 1kHz
Mod Dev : 3.0kHz
[Narrow]
1) TEST CH: Low, Center, High
(3
points)
2) SSG otuput: –114dBm
AF Freq : 1kHz
SSG MOD: 1.5kHz
4. Low RSSI
*Note
[Wide]
1) TEST CH: Low, Center, High
(3 points)
2) SSG otuput: –120dBm
AF Freq : 1kHz
Mod Dev : 3.0kHz
[Narrow]
1) TEST CH: Low, Center, High
(3 points)
2) SSG otuput: –120dBm
AF Freq : 1kHz
SSG MOD: 1.5kHz
5. High RSSI
*Note
[Wide]
1) TEST CH: Low, Center, High
(3 points)
2) SSG otuput: –80dBm
AF Freq : 1kHz
Mod Dev : 3.0kHz
[Narrow]
1) TEST CH: Low, Center, High
(3 points)
2) SSG otuput: –80dBm
AF Freq : 1kHz
SSG MOD: 1.5kHz
*Note
1) If Wide Band RSSI tuning is selected, it will align for the Wide band only.
2) If Narrow Band RSSI tuning is seleted, Wide band and Narrow band will be align with same tuning value.
Содержание TK-2402