TK-2302/2302
(
V
)
/2306
40
LEVEL DIAGRAM
Receiver Section
T
ransmitter Section
)z
H
k
1(
F
A
RF (Center Frequency)
RF (Center Frequency)
–121.0dBm
–120.5dBm
–118.0dBm
–104.0dBm
–106.5dBm
–100.5dBm
210mV
130mV
IF1 (38.85MHz)
IF2 (450kHz)
AF (1kHz)
SP
500mW
C150
C257
Q204
C238
Q203
Q202
XF201
C217
C215
IC201
FM IF
SYSTEM
C390
AQUA-L
IC308
C391
IC309
15mV
rms
120mV
rms
1.6dBm
8.2dBm
37.1dBm
–4.0dBm
5.0W
MIC
AQUA-L
IC308
C45
VCO
PLL
C51
C81
IC2
Q9
C87
RXLO
D10
C102
Q101
C108
Q102
Q105
C150
T
o
make measurements in the AF section, connect the AC level meter
.
(ANT input: –53dBm, 1kHz FM, 3kHz DEV (WIDE).)
In the RF section,use 1000pF coupling capacitor
.
(The display shows the SSG input value required to obtain
12dB SINAD without Local Level.)
AG is set to the MIC Input becomes 3kHz DEV
. at 1kHz MOD. (WIDE).
T
o
make measurements in the AF section, connect the AC level meter
.
In the RF section, use 1000pF coupling capacitor
.