TK-2202L
17
1.Frequency
1) CH:High
Frequency counter ANT
VR1
High frequency
Note:
After replacing
Adjust
2) PTT:ON
±50Hz
the TCXO (X1) align
frequency.
2.High power TEST CH: Low
Power meter
Programming
5.0W
±0.1W
Adjust
Low’
Ammeter
Software:KPG-87D
2.0 A or less
Center
High’
High
(5 points)
BATT terminal voltage:7.5V
PTT:ON
3.Low power
TEST CH: Low
1.05W
±0.1W
Adjust
Low’
1.0 A or less
Center
High’
High
(5 points)
BATT terminal voltage:7.5V
PTT:ON
4.DQT
TEST CH: Center
Power meter
Make the
balance Adjust
Low
Deviation meter
demodulation
[Wide]
High
Oscilloscope
wave into
(3 points)
AG
square waves.
LPF:3kHz
AF VTVM
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
ADJUSTMENT
Common Section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark
1.Setting
1) BATT terminal voltage:7.5V
2) SSG standard modulation
[Wide] MOD:1kHz,DEV:3kHz
[Narrow] MOD:1kHz,DEV:1.5kHz
2.VCO lock
1) CH:High
Power meter
ANT
TC2
4.0V
±0.1V
voltage
2) CH:Low
DVM
CV
Check
0.6V or more
RX
3.VCO lock
3) CH:High
TC1
4.2V
±0.1V
voltage
PTT:ON
TX
4) CH:Low
Check
0.6V or more
PTT:ON
Transmitter Section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark