TH-K4AT/K4E
41
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Unit
Terminal
Unit
Parts
Method
Remarks
7.Tone
deviation
8.DCS
deviation
9.VOX
Sensitivity
Write
Switch to Adjustment mode
and carry out the operations
for adjustment item M.
(Refer to page 33)
Detector: P-P/2
HPF: OFF
LPF: 3kHz
De-emphasis: OFF
TX power: Low
1)LCD display: DVL,
Frequency: 430.000MHz
PTT: ON
2)LCD display: DVC,
Frequency: 435.000MHz
PTT: ON
3)LCD display: DVH,
Frequency: 439.990MHz
PTT: ON
Switch to Adjustment mode
and carry out the operations
for adjustment item N.
(Refer to page 33)
Detector: +P HOLD
HPF: OFF
LPF: 3kHz
De-emphasis: OFF
TX power: Low
1)LCD display: DVL,
Frequency: 430.000MHz
PTT: ON
2)LCD display: DVC,
Frequency: 435.000MHz
PTT: ON
3)LCD display: DVH,
Frequency: 439.990MHz
PTT: ON
Switch to Adjustment mode
and carry out the operations
for adjustment item O.
(Refer to page 34)
TX power: Low
1)LCD display: VOX1
Frequency: 435.000MHz
AG: 1kHz/80mV
2)LCD display: VOX9
Frequency: 435.000MHz
AG: 1kHz/1.5mV
Linear detector
AG
ANT
MIC
Encoder
[MENU]
Encoder
[MENU]
Encoder
[MENU]
Encoder
[MENU]
Encoder
[MENU]
Encoder
[MENU]
[MENU]
[MENU]
Write
Write
Write
Write
Write
Write
Write
Write
0.8kHz ±50Hz
0.8kHz ±50Hz
ADJUSTMENT
TX-RX
(A/3)