TH-K4AT/K4E
36
1.RX BPF
Squelch level: 0
Adjust
1) Frequency: 435.050MHz
SSG
TX-RX
ANT
VOL
Turn the VOL knob 0.63V
SSG output: –53dBm (501 uV) Oscilloscope
(A/3)
SP
knob
to obtain 0.63V AF
SSG MOD: 1kHz
Distortion meter
output.
SSG DEV: 3kHz
AF V.M
Switch to Adjustment mode
Dummy load
and carry out the operations
for adjustment item E.
(Refer to page 29)
2) LCD display: BPL
Encoder
Write
Max Sensitivity
Frequency: 400.050MHz
[MENU]
SSG: –119dBm (0.25 uV)
3) SSG: –110dBm (0.707 uV)
Check
12dB SINAD or
more
4) LCD display: BPC
Encoder
Write
Max Sensitivity
Frequency: 435.050MHz
[MENU]
SSG: –120dBm (0.22 uV)
5) SSG: –120dBm (0.22 uV)
Check
12dB SINAD or
more
6) LCD display: BPH
Encoder
Write
Max Sensitivity
Frequency: 469.990MHz
[MENU]
SSG: –121dBm (0.199 uV)
7) SSG: –113dBm (0.501uV)
Check
12dB SINAD or
more
2.IF response 1) Frequency : 469.990MHz
SSG
Check
12dB SINAD or
Check
SSG Frequency: 450.565MHz Oscilloscope
less
SSG output: –53dBm (501uV) Distortion meter
Note:
If the
SSG MOD: 1kHz
specification is not
SSG DEV: 3kHz
satisfied, repeat the
AF output: 0.63V/8
Ω
operations for
2) Frequency : 400.050MHz
“1. RX BPF
SSG Frequency: 380.625MHz
Adjust”.
SSG output: –53dBm (501uV)
3) Frequency : 435.000MHz
SSG Frequency: 415.575MHz
SSG output: –53dBm (501uV)
3.Squelch /
Switch to Adjustment mode
SSG
ANT
S-meter
and carry out the operations
Write
for adjustment item C.
(Refer to page 28)
1) LCD display: SQ1
[MENU]
Write
Note:
In the
Frequency: 435.050MHz
Squelch adjust
SSG: –125dBm (0.126uV)
ments, all 4
Squelch 2) LCD display: SQ2
[MENU]
Write
adjusting points
Frequency: 435.050MHz
including the S-
SSG: –120dBm (0.22uV)
meter must be
adjusted.
ADJUSTMENT
Receiver section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Unit
Terminal
Unit
Parts
Method
Remarks