RXD-251/301/351/371S/A3
14
ADJUSTMENT
CD MECHA.
UNIT
R07
VR01
VC
IC01
48pin
RF
R07A
R06
FIG.
(a)
No.
ITEM
INPUT
SETTINGS
OUTPUT
SETTINGS
ALIGNMENT
POINTS
ALIGN
FOR
PLAYER
SETTINGS
1
LASER POWER
−
Apply the sensor section
of optical power meter
on the pickup lens.
−
On the power from
0.08 to 0.15 mW,
when the diffraction
grating is correctly
aligned with the RF
level of 0.6 Vp-p or
more.
Press the
PLAY/PAUSE key.
Pickup
FOCUS ERROR
BIAS
Test disc
Type 4
Connect an oscilloscope
as follows.
CH1 : RF (R07A)
GND : VC (IC01, 48 pin)
FE BIAS
VR01
Optimum eye pattern
Press the
PLAY/PAUSE key.
Note:
Type 4 disc : SONY YEDS-18 Test Disc or equivalent.(KTD-0
✽
)
0.08
0.15 mW
Optical power meter
2
(a) Laser power
ALIGNMENT POINT