Kenwood PS10-35 Скачать руководство пользователя страница 2

REGULA

TED

DC

POWER

SUPPLIES

PS

SERIES

59

PS SERIES

REGULATED DC POWER SUPPLIES

Safety

(Fail-Safe Function)

For safety, the switching operation is stopped (output off status)
and the AC power relay is interrupted while a protection function
is operating.

Output over-voltage protection (OVP)

When the output voltage exceeds the OVP setting value, the
switching operation (oscillation) is stopped and the output is
turned off.

Output over-current protection (OCP)

Increase in the output current to 110% or more of the rated current
is detected by a protection circuit, which stops the switching
operation and interrupts the AC power relay.

Over-heat protection (OHP)

When the heat sink temperature reaches about 100

, the

switching operation is stopped and the AC power relay is
interrupted.

Input power abnormality protection

In case of input over-voltage, input voltage drop or an over-current
due to internal abnormality, the switching operation is stopped
and the output is turned off.

Alarm (power abnormality) signal

When the output over-current, input over-voltage or input over-
current is detected, when the over-heat protection circuit is
activated or when the power is switched off, an alarm signal is
generated to turn the output off and interrupt the AC power relay.

Power relay off signal

When  trouble occurs on the user side, etc., the power relay is
interrupted by an external signal.

(Rush current protection circuit)

The rush current protection circuit is activated at the moment of
the power is switched on to reduce the input surge current.

GP-IB System Compatibility

In addition to the output voltage and current control capabilities
and status signal outputs, the output on/off, power on/off control
and remote/local switches are provided. The GP-IB control is also
possible optionally (when the optional GP-600 is combined.)

Wide Applications

Control operations include control by an external voltage or
resistance of the output voltage and current.

Low Noise

The temperature-sensitive fan motor reduces the rotation speed
when the load is light or the ambient temperature is low to prevent
noise.

Front Air Intake

The forced air cooling system intakes air through the front panel
and increases the packing density in case the power supply is
mounted in a device or rack. The front grill incorporate an air filter
to improve dust protection.

PS6-60
PS10-35
PS20-18
PS36-10
PS60-6

PS6-120
PS10-70
PS20-36
PS36-20
PS60-12

PS20-54
PS36-30
PS60-18

Содержание PS10-35

Страница 1: ...s are also provided including remote control functions with GP IB control capability which is possible when the optional GP 600 is used Compact Size Light Weight High Efficiency Thanks to the advanced switching method the PS Series power supplies are both compact and light with less than half the mass and volume of previous power supply models resulting in an excellent space factor and high effici...

Страница 2: ...ircuit is activated or when the power is switched off an alarm signal is generated to turn the output off and interrupt the AC power relay Power relay off signal When trouble occurs on the user side etc the power relay is interrupted by an external signal Rush current protection circuit The rush current protection circuit is activated at the moment of the power is switched on to reduce the input s...

Страница 3: ...for remote control CV CONTROL Control by an external voltage SELECT Control by an external resistance Normal mode S1 Control by an external resistance Fail safe mode Remote local switching of output current voltage resistance mode selection for remote control CC CONTROL Control by an external voltage SELECT Control by an external resistance Normal mode Control by an external resistance Fail safe m...

Страница 4: ...ector Output voltage Output voltage 0 to 10V 0 to10kΩ to 0Ω S terminal J1 Output current Output current 0 to 10V 0 to10kΩ to 0Ω S terminal J1 Output ON OFF Output ON Photo diode ON Floating Community common J1 Power ON OFF AC power relay ON Photo diode ON Floating Community common J1 CV mode signal At CV operation Photo transistor ON Floating Community common J1 CC mode signal At CC operation Phot...

Страница 5: ...ifications Environmental condition Temperature humidity for operation 0 to 50 30 to 80 RH Temperature humidity for storage 20 to 70 20 to 80 RH Cooling system Forced air fan front air intake type Functions Automatic output switch resetting voltage current limit switch preset OVP Case dimensions Type I 70 W 124 H 350 5 D mm Type II 140 W 124 H 350 5 D mm Type III 210 W 124 H 350 5 D mm Accessories ...

Страница 6: ...e rated voltage Figure of Case dimensions 1 RB 600A 1 2 rack width RB 600B 1 3 rack width RB 600C 1 6 rack width CC constant current characteristic Others Ripple Line regulation Load regulation Input Current Case dimensions Weight mA rms 0 2 mA 0 2 mA AC 100 200V A Type kg approx 120 5 5 8 5 I 3 0 260 10 10 16 10 II 5 5 70 5 5 8 5 I 3 0 160 10 10 15 9 II 5 5 40 5 5 8 5 I 3 0 92 10 10 15 9 II 5 5 1...

Отзывы: