1-50 (No.RA033<Rev.001>)
10. RSSI
Refer-
ence Ad-
just
[Analog
Wide]
FPU Test mode
1) Adjust Item: [RSSI Ref (Ana-
log Wide)]
Connect the SSG to the RX
ANT.
SSG setting
Frequency: [Low], [Low’] [Cen-
ter], [High’], [High]
Output: 12dB SINAD level -1dB
MOD: 1.0kHz
DEV: ±3.0kHz
SSG
Audio ana-
lyzer
Rear RX ANT
PC
ADJ
Press [Apply] button to store
the adjustment value.
Remark:
Measure 12dB SINAD in
Analog Narrow before-
hand, when adjusting "12.
RSSI Reference Adjust
[NXDN Very Narrow]"
11. RSSI
Refer-
ence Ad-
just
[Analog
Narrow]
FPU Test mode
1) Adjust Item: [RSSI Ref (Ana-
log Narrow)]
Connect the SSG to the RX
ANT.
SSG setting
Frequency: [Low], [Low’] [Cen-
ter], [High’], [High]
Output: 12dB SINAD level -1dB
MOD: 1.0kHz
DEV: ±1.5kHz
12. RSSI
Refer-
ence Ad-
just
[NXDN
Very Nar-
row]
FPU Test mode
1) Adjust Item: [RSSI Ref
(NXDN Very Narrow)]
Connect the SSG to the RX
ANT.
SSG setting
Frequency: [Low], [Low’] [Cen-
ter], [High’], [High]
Output: 12dB SINAD level
forAnalog Narrow -1dB
MOD: OFF
13. Low
RSSI Ad-
just [Ana-
log Wide]
FPU Test mode
1) Adjust Item: [Low RSSI (Ana-
log Wide)]
Connect the SSG to the RX
ANT.
SSG setting
Frequency: [Low], [Low’] [Cen-
ter], [High’], [High]
Output: -118dBm (0.28
μ
V)
MOD: 1.0kHz
DEV: ±3.0kHz
SSG
Rear RX ANT
PC
ADJ
Press [Apply] button to store
the adjustment value.
14. Low
RSSI Ad-
just [Ana-
log
Narrow]
FPU Test mode
1) Adjust Item: [Low RSSI (Ana-
log Narrow)]
Connect the SSG to the RX
ANT.
SSG setting
Frequency: [Low], [Low’] [Cen-
ter], [High’], [High]
Output: -118dBm (0.28
μ
V)
MOD: 1.0kHz
DEV: ±1.5kHz
Item
Condition
Measurement
Adjustment
Specifications / Remarks
Test-
equipment
Unit
Terminal Unit
Parts
Method