1-44 (No.RA033<Rev.001>)
• Signaling number 1 is used for link test with voice.
• Signaling number 2 is used for TX modulation signal quality test. i.e, TX adjacent channel power, FSK error, Occupied bandwidth,
Emission mask, etc.
• Signaling number 3 is used for TX deviation test. If the modulation mode is very narrow, the modulation frequency is 600Hz. If the
modulation mode is narrow, the modulation frequency is 1200Hz.
Fig.1
Fig.2
Fig.3
Fig.4
Fig.5
Fig.6
Delta Marker 1 and 2
f0 +/- 3.5MHz : 2dB max
Delta Marker 3
f0 - 11.5MHz : 16 - 18dB
Delta Marker 4
f0 + 24MHz : more than 25dB
Center freq : f0 + 1.5MHz
137.5MHz
Delta Marker 1 and 2
f0 +/- 3.75MHz : 2dB max
Delta Marker 4
f0 + 24MHz : more than 25dB
Delta Marker 3
f0 -14.7MHz : more than 17dB
Delta Marker 1 and 2
f0 +/- 4MHz : 2dB max
Delta Marker 4
f0 + 24MHz : more than 25dB
Delta Marker 3
f0 -19MHz : more than 17dB
Delta Marker 1 and 2
f0 +/- 4.25MHz : 2dB max
Delta Marker 4
f0 + 24MHz : more than 25dB
Delta Marker 3
f0 -24MHz : more than 17dB
Delta Marker 1 and 2
f0 +/- 4.5MHz : 2dB max
Delta Marker 4
f0 + 24MHz : more than 25dB
Delta Marker 3
f0 -24MHz : more than 17dB
f0 +/- 15kHz :
more than 20dB
f0 +/- 7.6kHz :
6dB max