(No.RA070<Rev.001>)1-43
4. Balance
<PC>
1) Adj item: [Balance]
2) Deviation meter
LPF: 3kHz/ HPF: OFF
3) Adj points: 10 points
[8TX L], [8TX C], [8TX H],
[8RX/TA L], [8RX/TA C],
[8RX/TA H], [9TX L], [9TX H],
[9RX/TA L], [9RX/TA H]
4) Press [Transmit] button.
Deviation
meter
Oscilloscope
[+], [-]
The Deviation of 20Hz frequency
is fixed.
Change the 2kHz adjustment
value to become the same
deviation of 20Hz within the
specified range.
<PC>
While PTT is ON click the check
box "2kHz Sine Wave" to change
the 20Hz/2kHz.
Press [Apply] button to store the
adjustment value.
<Panel>
While PTT is ON, press the [
]
button to change the 20Hz/2kHz.
Press [ ] button to store the
adjustment value.
2kHz Tone
deviation is
within ± 1.0%
of 20Hz tone
deviation.
<Panel>
1) Adj item: [An BAL]
2) Deviation meter
*Same as above
3) Adj points: *Same as above
4) PTT : ON
[
], [
]
5. Maximum
Deviation
adjust
[Analog Wide
5k]
<PC>
1) Adj item: [Maximum Deviation
(Analog Wide 5k)]
2) Deviation meter
LPF: 15kHz/ HPF: OFF
3) Adj points: 6 points
[8TX L], [8TX C], [8TX H],
[8RX/TA L], [8RX/TA C],
[8RX/TA H]
4) Press [Transmit] button.
Deviation
meter
Oscilloscope
[+], [-]
Write fixed value "489" for each
adjustment point. Transmit at
each adjustment point and check
that the deviation is within the
Specifications.
Press [Apply] button for
<PC>
, or
[ ] button for
<Panel>
to store
the adjustment value.
4150~4250Hz
<Panel>
1) Adj item: [Aw ADEV]
2) Deviation meter
*Same as above
3) Adj points: *Same as above
4) PTT : ON
[
], [
]
[Analog Wide
4k]
<PC>
1) Adj item: [Maximum Deviation
(Analog Wide 4k)]
2) Deviation meter
LPF: 15kHz/ HPF: OFF
3) Adj points: 6 points
[8TX L], [8TX C], [8TX H],
[8RX/TA L], [8RX/TA C],
[8RX/TA H]
4) Press [Transmit] button.
Deviation
meter
Oscilloscope
[+], [-]
Write fixed value "487" for each
adjustment point.
Transmit at each adjustment point
and check that the deviation is
within the Specifications.
Press [Apply] button for
<PC>
, or
[ ] button for
<Panel>
to store
the adjustment value.
3310~3410Hz
<Panel>
1) Adj item: [As ADEV]
2) Deviation meter
*Same as above
3) Adj points: *Same as above
4) PTT : ON
[
], [
]
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
<PC>: PC tuning mode
<Panel>: Panel tuning mode
Unit Parts
Method
Содержание NX-3400