(No.RA070<Rev.001>)1-53
[DSP
(Standby)]
<PC>
1) Adj item: [RSSI Reference
(Analog Narrow) 3 DSP
(Standby)]
2) SSG output: 12dB SINAD level
-3dB (MOD: 1kHz/±1.5kHz)
3) Adj points: 5 points
[8RX/TA L], [8RX/TA C],
[8RX/TA H], [9RX/TA L],
[9RX/TA H]
SSG
Distortion
meter
Oscilloscope
[+], [-]
After input signal from SSG;
Press [Acquire Monitored Value]
button and then press [Apply]
button for
<PC>
, or press [ ]
button for
< Panel>
, to store the
adjustment value.
<Panel>
1) Adj item: [An RSSI 3]
2) SSG output: *Same as above
3) Adj points: *Same as above
[
], [
]
[RF IC
(Standby)]
<PC>
1) Adj item: [RSSI Reference
(Analog Narrow) 4 RF IC
(Standby)]
2) SSG output: 12dB SINAD level
-3dB (MOD: 1kHz/±1.5kHz)
3) Adj points: 5 points
[8RX/TA L], [8RX/TA C],
[8RX/TA H], [9RX/TA L],
[9RX/TA H]
SSG
Distortion
meter
Oscilloscope
[+], [-]
After input signal from SSG;
Press [Acquire Monitored Value]
button and then press [Apply]
button for
<PC>
, or press [ ]
button for
< Panel>
, to store the
adjustment value.
<Panel>
1) Adj item: [An RSSI 4]
2) SSG output: *Same as above
3) Adj points: *Same as above
[
], [
]
4.Squelch
Open
[Analog Wide
5k]
<PC>
1) Adj item: [Squelch Open (Analog
Wide 5k)]
2) SSG output: 12dB SINAD level
-3dB (MOD: 1kHz/±3kHz)
3) Adj points: 5 points
[8RX/TA L], [8RX/TA C],
[8RX/TA H], [9RX/TA L],
[9RX/TA H]
SSG
Distortion
meter
Oscilloscope
[+], [-]
After input signal from SSG;
Press [Acquire Monitored Value]
button and then press [Apply]
button for
<PC>
, or press [ ]
button for
< Panel>
, to store the
adjustment value.
<Panel>
1) Adj item: [Aw SQL]
2) SSG output: *Same as above
3) Adj points: *Same as above
[
], [
]
[Analog Wide
4k]
<PC>
1) Adj item: [Squelch Open (Analog
Wide 4k)]
2) SSG output: 12dB SINAD level
-3dB (MOD: 1kHz/±2.4kHz)
3) Adj points: 5 points
[8RX/TA L], [8RX/TA C],
[8RX/TA H], [9RX/TA L],
[9RX/TA H]
SSG
Distortion
meter
Oscilloscope
[+], [-]
After input signal from SSG;
Press [Acquire Monitored Value]
button and then press [Apply]
button for
<PC>
, or press [ ]
button for
< Panel>
, to store the
adjustment value.
<Panel>
1) Adj item: [As SQL]
2) SSG output: *Same as above
3) Adj points: *Same as above
[
], [
]
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
<PC>: PC tuning mode
<Panel>: Panel tuning mode
Unit Parts
Method
Содержание NX-3400
Страница 70: ...1 70 No RA070 Rev 001 ESN Label Layout Note Cut a ESN Label at dotted line ESN Label ...
Страница 82: ... No RA070 Rev 001 2 12 2 12 No RA070 Rev 001 MEMO ...
Страница 84: ... MEMO No RA070 Rev 001 2 14 ...
Страница 97: ...MEMO ...
Страница 98: ... No RA070 Rev 001 JKS Printed in Japan JVC KENWOOD Corporation Communications Systems Division ...