REPEATER OPERATION

Note: 

Please consult your dealer for programming the repeater. Due 

to the frequency stability on the 6.25 kHz bandwidth channel, when 
operating the repeater using an optional OCXO unit, allow the unit to 
warm up for 24 hours after turning the power on. 
After turning on the power, wait for approximately 10 seconds for 
the VCXO or 5 minutes for the OCXO (when mounting) to warm up. 
During this time, the CH/STATUS Display will blink. The keys will 
function when they are pressed.

When power is applied to the unit, the POWER indicator lights 
green. Turn the VOLUME control clockwise until a click sounds, to 
unmute the audio. Rotate to adjust the audio. Turn the VOLUME 
control counterclockwise fully to mute the audio.

The BUSY indicator lights green while receiving a signal and the 
TX indicator lights red while transmitting.

 Rear Panel

a

  RX IN jack

Connect an RX antenna or a duplexer to this BNC 
receptacle.

b

  TEST/SPKR jack

Test input/output jack.  Connect an external speaker to 
this jack.

c

  CONTROL I/O jack

Connect a repeater controller or a remote panel to this 
DB-25 interface.

d

  SYNC 1 / 2 jack

Connect to another repeater to use synchronous frame 
signaling for digital trunking.

e

  LAN jack

Connect to Ethernet.

CONTROLS AND FUNCTIONS

 Front Panel

f

  REF OUT jack

Connect to another repeater within the site to supply a 
reference signal.

g

  REF IN jack

Connect from another repeater within the site to receive a 
reference signal.

h

  FUSE

Insert 7.5 A blade fuse into this fuse holder.

i

  DC 13.8V jack

Connect a 13.8 V DC power supply to this jack.

j

  TX OUT jack

Connect a TX antenna or a duplexer to this BNC 
receptacle.

a

b

d

e

f

g

c

TEST/SPKR

RX

TX

CONTROL  I/O

SYNC

1

2

LAN

REF  OUT

REF  IN

FUSE

75

DC  13.8V

h

i

j

TRANSCEIVER OPERATION

 Receive

  

Adjust the volume to your desired level.  You may need to 
readjust the volume if you are having interference while 
receiving a message from your dispatcher or another member 
in your fl eet. 

  The 

BUSY indicator lights green while a signal is being 

received.

 Transmit

1  Listen to the channel before transmitting, to make sure it 

is not being used.

2  Press the microphone PTT switch, then speak in your 

normal speaking voice.

The TX indicator lights red while transmitting.

3  When you fi nish speaking, release the PTT switch.

a

b

d

e

f

g

h

i

c

MICROPHONE

VOLUME

COM

OFF/

POWER

CTRL

OCXO

BUSY

TX

1 2

MON TAKE

OVER

RPT

DISABLE

A

B

C

3 4 5 6 7 8

STATUS

j

k

l

a

  Speaker

b

  CH/STATUS Display

Two 17-segment digits display the channel number, name, 
or status.

c

  STATUS indicator

Indicates the status of the repeater. (NXDN mode)

d

  Programmable Function keys

Press these keys to activate their programmable functions.

e

  COM jack

Connect to the PC using a RS-232C standard DB9 
(Female) cross cable.

f

  VOLUME control

Turn clockwise until a click sounds, to unmute the audio. 
Rotate to adjust the audio. Turn counterclockwise fully to 
mute the audio.

g

  MICROPHONE jack

Connect a microphone to this 8-pin modular jack.

h

  POWER indicator

Lights green when power is supplied to the DC 13.8V jack. 
Blinks red when an abnormal voltage is present. While 
blinking, the repeater cannot be used.

i

  TX indicator

Lights red while transmitting.

j

  BUSY indicator

Lights green while a signal is being received.

k

  OCXO indicator

The OCXO indicator shows the state of the reference 10 
MHz oscillator :

 

Lights Green when using a reference signal from an 

optional OCXO unit (KXK-3).

 

Lights Orange when using a reference signal from another 

repeater.

 

Lights red when no reference signal is available or when 

an error occurs.

 

Does not light when the reference signal is an internal 

VCXO signal.

l

  CTRL indicator

The CTRL indicator shows the control channel status 
while using Digital trunking :

 

Lights Green when the repeater is used as control 

channel.

 

Blinks Green when using a non-dedicated control channel.

Содержание NEXEDGE NXR-900-K

Страница 1: ...NXR 900 K INSTRUCTION MANUAL B62 1994 00 09 08 07 06 05 04 03 02 01 00 MANUAL DE INSTRUCCTIONES MODE D EMPLOI BASE REPETIDOR DIGITAL DIGITAL BASE REPEATER BASE RELAIS NUMÉRIQUE ...

Страница 2: ...e following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer for technical assistance The AMBE 2 voice coding Technology embodied in this product is protected by intellectual property rights including patent rights c...

Страница 3: ...may need to readjust the volume if you are having interference while receiving a message from your dispatcher or another member in your fleet The BUSY indicator lights green while a signal is being received Transmit 1 Listen to the channel before transmitting to make sure it is not being used 2 Press the microphone PTT switch then speak in your normal speaking voice The TX indicator lights red whi...

Страница 4: ...onter le code objet ou de quelque manière que ce soit de convertir le code objet en une forme lisible par l homme N de brevets américains 5 870 405 5 826 222 5 754 974 5 701 390 5 715 365 5 649 050 5 630 011 5 581 656 5 517 511 5 491 772 5 247 579 5 226 084 et 5 195 166 ATTENTION Ce répéteur est conçu pour une utilisation en tant que station de base fixe avec l antenne située à l extérieur sur le ...

Страница 5: ...es surviennent lors de la réception d un message de votre répartiteur ou d un autre membre de votre groupe L indicateur vert BUSY s allume lors de la réception d un signal Transmission 1 Ecoutez le canal avant la transmission afin de vous assurer qu il n est pas utilisé 2 Appuyez sur le commutateur PTT du microphone ensuite parlez sans changer votre voix L indicateur rouge TX s allume lors de la t...

Страница 6: ... el hombre Números de patente EE UU Nº 5 870 405 Nº 5 826 222 Nº 5 754 974 Nº 5 701 390 Nº 5 715 365 Nº 5 649 050 Nº 5 630 011 Nº 5 581 656 Nº 5 517 511 Nº 5 491 772 Nº 5 247 579 Nº 5 226 084 y Nº 5 195 166 PRECAAUCIÓN Este repetidor está pensado para utilizarse como estación base fija con la antena situada en exteriores ya sea en el tejado o en una torreta de antena El repetidor está diseñado par...

Страница 7: ...pción de un mensaje procedente de su distribuidor de mensajes o de otro miembro de la flota El indicador BUSY se ilumina de color verde durante la recepción de una señal Transmisión 1 Escuche el canal antes de transmitir para asegurarse de que no está en uso 2 Presione el conmutador PTT del micrófono y hable con su tono de voz habitual El indicador TX se ilumina de color rojo durante la transmisió...

Страница 8: ......

Отзывы: