NX-320
48
ADJUSTMENT (K TYPE)
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
9. DTMF
Deviation
*4
[Narrow]
1) Adj item: [DTMF]
Adjust:
[
✳✳✳✳
.]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [DTMF
Deviation (Analog
Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
Press
[Transmit]
button.
Press [Apply] but-
ton to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
Selector
[PC test
mode]
[ ],[ ]
Write the value as
followings.
540 (Reference
value)
1.25kHz±0.05kHz
[Wide]
1) Adj item: [DTMF]
Adjust:
[
✳✳
.
✳
.
✳
.]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [DTMF
Deviation (Analog
Wide)]
PTT:
Press
[Transmit]
button.
Press [Apply] but-
ton to store the
adjustment value.
2.50kHz±0.05kHz
10. Single
Tone
Deviation
*4
[Narrow]
1) Adj item: [TONE]
Adjust:
[
✳✳✳✳
.]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [Single
Tone Deviation
(Analog Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
Press
[Transmit]
button.
Press [Apply] but-
ton to store the
adjustment value.
Write the value as
followings.
513 (Reference
value)
1.50kHz±0.05kHz
[Wide]
1) Adj item: [TONE]
Adjust:
[
✳✳
.
✳
.
✳
.]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [Single
Tone Deviation
(Analog Wide)]
PTT:
Press
[Transmit]
button.
Press [Apply] but-
ton to store the
adjustment value.
3.00kHz±0.05kHz
11. MSK
Deviation
*4
[Narrow]
1) Adj item: [MSK]
Adjust:
[
✳✳✳✳
.]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [MSK
Deviation (Analog
Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
Press
[Transmit]
button.
Press [Apply] but-
ton to store the
adjustment value.
Write the value as
followings.
513 (Reference
value)
1.50kHz±0.05kHz
[Wide]
1) Adj item: [MSK]
Adjust:
[
✳✳
.
✳
.
✳
.]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [MSK
Deviation (Analog
Wide)]
PTT:
Press
[Transmit]
button.
Press [Apply] but-
ton to store the
adjustment value.
3.00kHz±0.05kHz