10
KRF-V5100D/V6100D
X08-3472-70 (1/3)
A
C
E
B
D
2
1
3
5
7
4
6
OSCILLATOR
OUT
MONITOR
PLAY IN
DVD
PLAY IN
VIDEO2
J901
C
Q601
S VIDEO
DETECT
DIGITAL
D601
AUDIO
DECODER
DIGITAL
CD/DVD
J601
A601
D605
VIDEO2
DVD
OPTICAL INPUT
COAXIAL
INPUT
∗
B
+3.3V
VCC
Y
C
Y
C
Y
C
8
GND
IN1
Y5
Y7
C7
C5
47P
100K
R905
C905
100K
R906
47P
C906
47P
75
R903
C903
75
R904
47P
C904
0.01
4
C910
3
2
VCC
IN2
SW2
5
IN3
SW1
6
OUT
7
10 1/4W
R916
C5
Y3
C7
100P
C918
+11.5V
0.01
C909
R908
0.1
C916
75
47u25
+
C912
CX
Y3
47P
75
R901
C901
75
R902
47P
C902
1
8
X601
R604
1M
R603
1M
4
2
1
3
R602
220
GND
6
7
5
C602
1000P
12.288MHz
CLR
B
A
C604
27P
1
3
2
C603
22P
RX/CX
VCC
8
6
7
14
0.01
C920
C919
0.01
GND
4
+2.5V
Q
5
SCDI0
R804
R803
R802
R801
R800
R799
R806
1 1/4W
R623 10K
+2.5V
0.01
R626
3.3K
C612
22
4.7K
4.7K
R633
R632
C607 22P
C675 22P
R610
220
C608
1000P
R601
220
+3.3V
R810
R605
10K
C601
0.01
C606
0.01
R609
100K
C605
0.01
1
R809
1
47u25
C616
+2.5V
R629 10K
C614
0.01
C615 470P
+
C613 2.2u50
R630
33K
+
R634
470
R631
1/4W
1
R805
0.01
0.01
100
+2.5V
R608
220
13
+3.3V
2
+2.5V
36
22
39
AU DATA1
AU DATA0
LR CLK
S CLK
M CLK
VD1
D GND1
AU DATA3
WR
LR CLK N1
FILT1
CMP REQ
31
CLK IN
22
30
29
FILT2
CLK SEL
32
33
CMP CLK
CMP DAT
22
28
22
27
AU DATA2
RESET
A GND
VA
C617
34
C618
36
35
DC
DD
38
37
39
23
S CLK N1
D GND3
22
22
26
25
24
VD3
S DATA N1
EXTMEM
22
21
20
ABOOT
R795 22
42
R638 22
R637 22
R692 22
40
41
40
42
41
C609
0.01
R793 22
R794 22
44
43
+2.5V
1
44
43
2
3.3K
R611
3
4
18
R624
220
R627
220
3.3K
R625
R628
220
C611
1000P
20
+2.5V
19
RD
A1
C610
12
0.01
16
CS
DATA0
19
18
17
D GND 2
DATA3
DATA2
DATA1
14
15
13
CP601
10K
R807
1
R614
220
DATA7
DATA6
DATA5
DATA4
VD2
11
8
9
10
A0
7
1/4W
CP602
10K
7
100u10
R690
470
1/4W
R691
4.7
+
C657
3
2
1
+5V
+5V
6
5
3.3K
R612
R613
220
6
R808
+2.5V
1/4W
1
C636
4700P
C637
4700P
R635
R644
75
75
C635
22P
C634
22P
22
R651
IC603
IC901
IC604
IC601
(X08-3472-70)
CAUTION:
For continued safety, replace
safety critical components only with man-
ufacturer's recommended parts (refer to
parts list).
indicates safety critical com-
ponents. For continued protection against
risk of fire, replace only with same type
and rating fuse(s). To reduce the risk of
electric shock, leakage-current or resis-
tance measurements shall be carried out
(exposed parts are acceptably insulated
from the supply circuit) before the appli-
ance is returned to the customer.
The DC voltage is an actual reading mea-
sured with a high impedance type volt-
meter with no signal input. The measure-
ment value may vary depending on the
measuring instruments used or on the
product.