2-Channel stereo configuration
This is the ‘standard’ stereo operation mode, with the amplifier driving 2 speakers in stereo (such as the Surround Back Left and
Surround Back Right speakers in a THX Surround EX
®
home theater system). The amplifier delivers its rated stereo power output
into each speaker.
1
Make sure that the KMF-X9000’s power cord is unplugged from the wall outlet before making any connections.
2
According to the speakers to be used, set the speaker impedance selector switch as follows:
•
For 2
Ω
speakers: Set the 2
Ω
(STEREO)/6
Ω
OVER switch to 2
Ω
(STEREO) and 6
Ω
OVER/2
Ω
switch to 2
Ω
.
•
For 6-16
Ω
speakers: Set the 2
Ω
(STEREO)/6
Ω
OVER switch to 6
Ω
OVER and 6
Ω
OVER/2
Ω
switch to 6
Ω
OVER.
3
Connect the amplifier as shown in the diagram.
CLIP
INDICATOR
CD 2 / TAPE 2
MONITOR
SURROUND
BACK
96kfs
DISCRETE 6.1
MATRIX 6.1
NEO : 6
PRO LOGIC
DTS-ES
* If you connect more than one pair of speakers to the KMF-X9000, move the
2
Ω
(STEREO)/6
Ω
OVER (THX)
switch to the
2
Ω
(STEREO)
position. The amplifier’s performance is not THX
®
-certified when the switch is set in the
2
Ω
(STEREO)
position.
Now you can plug the power cord of this unit into the AC outlet!
CAUTION:
Before reconnecting a speaker cord or switching a selector switch, turn OFF the power and unplug the power
cord to avoid malfunctions or damage to the unit.
Preamplifier
Audio cord (supplied)
To wall AC outlet
Speakers
(2
Ω
-16
Ω
)
* In the case of 2
Ω
ON : +12 V
OFF : OPEN (or GND)
NC
GND
KRF-X9995D
For RELAY CONTROL connec-
tion to KRF-X9995D or other
compatible unit, see page 6.
Left
(L SURROUND
BACK)
Right
(R SURROUND
BACK)
In the case of 6
Ω
Stereo mini-plug cord (supplied)