(No.WA049<Rev.001>)14/26
4.2.5.1
Operations
4.2.6 TUNER Setting Adjustment Mode
4.2.6.1
Operation
4.2.6.2
Operation in AUTO Adjustment Mode
Operation
Display content
Details
ACCENT
S meter voltage
judgment display
S meter value
xx: Current S meter value
Determination result
OK: Within S meter voltage spec
NG: Out of S meter voltage spec
- - : No LEVEL OFFSET adjustment
In addition, upon enter to this mode, P-CON is
turned ON.
When a judgment result is OK, P-CON is turned off.
Upon exit, P-CON still remain OFF.
When a judgment result is NG, P-CON is kept ON
condition.
Upon exit, P-CON still remain ON.
It is able to enter into this mode by remote control
operation.
ACCENT TUNER IC display
Display TUNER IC version
SEARCH
BAND switch
operation
Execute Band Switch as shown in the following ta-
ble every time Band key is pressed in each type.
M
S
–
T
x :
x
O
R
K
M
S
–
T
x :
x
N
R
G
M
S
–
T
x :
x
–
R
–
T
A
O
M
D
S
R
M
F
1
–
3
7
9
9
A
A
Operation
Display content
Details
DISP
Shift to TUNER
setting mode
Shift to TUNER setting mode after switching to
98.3MHz
<SG setting values>
Frequency: 98.3MHz, Modulation frequency:
1kHz, Modulation mode: MONO, Modulation:
OFF, Deviation: 40kHz, ANT input level: 34dBuV
In addition, upon enter to this mode, P-CON is
turned ON.
It is able to enter into this mode by remote control
operation.
(Upon remote control press, it will immediately
start Tuner Auto Adjustment Mode.)
SEARCH
(Toggle)
AUTO Adjustment
Mode
Select TUNER adjustment method (AUTO) using
SEARCH key.
S-xx: Current S meter value (Hex)
L-xx: Level offset value (Hex)
∗
In case that the level offset value is not adjusted
(0xFF or 0x00), display "- -".
S
A
–
–
x
x
x
L
x
Operation
Display content
Details
VOL PUSH Adjustment start
Start adjustment (Start Auto adjustment, and tran-
sit to Success/Failure display depending on the
adjustment result)
It is able to enter into this mode by remote control
operation.
S
A
–
–
x
x
x
L
x