![Kenwood KDC-MP6090R Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/kenwood/kdc-mp6090r/kdc-mp6090r_service-manual_1955821007.webp)
KDC-MP6090R/MP7018/MP8017
7
Pin No.
Pin Name
I/O
Description
Processing Operation
48-51
NC
O
Not used (N.C.)
52
ILL-ON
O
Illumination AVR on/off control output
"Hi": POWER ON mode except panel detached or
panel mask position
53
M-MUTE L
I
Mute request (Lch) from CD MECHA. MI-COM. "Lo": Mute request
54
M-MUTE R
I
Mute request (Rch) from CD MECHA. MI-COM. "Lo": Mute request
55
BVDD
-
Power supply connection terminal
Connected to BU 5V lines.
56
BVSS
-
Ground connection terminal
Connected to GND lines.
57
M-RST
O
Reset output to CD MECHA. MI-COM.
"Lo": Reset
58
M-STOP
O
Stop request to CD MECHA. MI-COM.
"Lo": Stop mode, "Hi": Operation mode
59
NC
O
Not used (N.C.)
60
LO/EJ
I/O CD MECHA. loading/Eject switching output "Lo": Loading, "Hi": Eject, "Hi-Z": Stop or Break
61
MOSW
O
CD mechanism loading motor control output "Hi": CD loading/eject action or Break, "Lo": other
62
NC
O
Not used (N.C.)
63
CD-SW3
I
Down & limit switch detection input
"Hi": Chucking, "Lo": Pickup most inner position
64
NC
O
Not used (N.C.)
65
L-CE
I/O CE output to LCD driver
66-69
NC
O
Not used (N.C.))
70
AVCONT
O
A/D converter reference voltage control output "Hi": Active, Connected to AVREF terminal.
71
AVDD
-
A/D converter power supply connection terminal Connected to BU 5V lines.
72
AVSS
-
A/D, D/A converter ground connection terminal Connected to GND lines.
73
AVREF
I
A/D converter reference voltage input terminal
74
PHONE
I
PHONE detection input
1V or less: TEL MUTE, 2.5V or greater: NAVI MUTE
75
NC(GND)
I
Not used (pull down to GND lines)
76
NC(GND)
I
Not used(pull down to GND lines)
77
SRT-SW2
I
SRT position detection input
Panel: (SW1, SW2)=(Hi, Hi)
Slide: (SW1, SW2)=(Hi, Lo)
78
SRT-SW1
I
SRT position detection input
Mask : (SW1, SW2)=(Lo, Lo)
79
NOISE
I
FM noise detection input
80
S-METER
I
S-meter input from F/E
81
R-DATA
I
Data input from the RDS decoder IC
Except RDS model: Not used (pull down to GND lines)
82
R-QUAL
I
Quality input from the RDS decoder IC
Except RDS model: Not used (pull down to GND lines)
83
IFC-OUT
I
F/E IFC OUT input terminal
"Hi": Station detected, "Lo": Not detected
84
NC(GND)
I
Not used (pull down to GND lines)
85
NC(GND)
I
Not used (pull down to GND lines)
86
NC
O
Not used (N.C.)
87
R-CLK
I
Clock input from the RDS decoder IC
Except RDS model: Not used(pull down to GND lines)
88
CH-REQC
I
Request input from changers
"Lo": Request
89
KEY-REQ
I
Communication request input form LCD driver IC
90
CD-SW1
I
Loading detection
"Lo": CD chucking.
91
CD-SW2
I
12cm disc detection terminal
When 12cm disc was detected, the input becomes
"Lo" temporarily.
92
NC
O
Not used (N.C.)
93
BU-DET
I
Momentary power down detection input
"Hi" : When momentary power down detected or BU OFF
"Lo" : BU ON
94
CH-DATAC
I
Data input from changers
95
CH-DATAH
O
Data output to changers
96
CH-CLK
I/O Clock input/output with changers
97
L-DATAL
I
Data input from the LCD driver IC
98
L-DATAS
I/O Data output to the LCD driver IC
99
L-CLK
I/O
Clock output to the LCD driver IC/Panel
detaching detection input (LCD Driver)
"Lo": Panel attached
100
PAN5V
O
Panel 5V control
"Hi": Panel attached, "Lo": Panel detached
MICROCOMPUTER'S TERMINAL DESCRIPTION