(No.WA001<Rev.001>)11/18
SECTION 4
ADJUSTMENT
4.1
TEST MODE
4.1.1 Panel
A symbol "
" in the key column indicates that the key should be pressed and held for 1 second or longer.
4.1.2 How to enter each Test Mode
∗
Transition to Test Mode shall be available during DC Error detection.
4.1.3 How to release each Test Mode
• Reset
• Momentary voltage drop
• ACC OFF
• POWER OFF
• Panel Detach
4.1.4 Production Test Mode
Press and hold [1] key and [3] key and reset.
z
Default status immediately after the mode activation
It shall be same as normal RST start in other settings than the following.
ACCENT
SEARCH
RETURN
VOL
KDC-152
Test Mode name
Operation
Production Test Mode
Press and hold [1] key and [3] key and reset.
Service Test Mode
In the STANDBY source, while pressing and holding [2] key, press [6] key for 7 seconds.
(Starting to press [2] key and [6] key at the same time can not be entered into the mode)
DC Error Information Mode
Press and hold [3] key and [6] key and reset.
Details
Difference in action
Period to prohibit TEL/LINE MUTE immediately after activation
(normally 10seconds)
1 second
Mecha Initialize Action
Prohibited
Write-in to E2PROM when detecting a DC error
Prohibited
Demo Mode ON/OFF Setting Menu
Prohibited
Power supply during ACC OFF (Back Up On)
MUTE terminal turns OFF after 2 seconds
BEEP sound
Beep with short-pressing in any functions