RXD-M47WM/LS-M47WM
10
ADJUSTMENT
FM Alignment:
Figure 6. FM Band Frequency Coverage Alignment
Connect FM S/G to ANT inputs (mod 1 kHz 22.5kHz dev.)
Step S/G
Frequency
Dial
Setting Indicator
Adjust
Remarks
1
87.5 MHz
Low end
Connect DC voltage
meter to test point Vt
and ground
L203
Adjust until Vt equal to:
2.5
±
0.05V
2
108 MHz
High end
Same as step 1
Confirm Vt: 7-9V
3
90.1 MHz
90.1 MHz
Connect oscilloscope
or VT/VM to speaker
jack
L204
Adjust until Maximum
output
4
106.1 MHz
106.1 MHz
Same as step 3
VC202
Adjust until maximum
output
5
Repeat steps 3 and 4 to minimize tracking error.
FM GENERATOR
DUMMY
ANTENNA
TP1
TEST UNIT
OSCILLOSCOPE
DUMMY LOAD
VTVM
R-OUT
L-OUT
GND
Figure 7. FM Band/Tracking
GROUND METER
Vt DC
TEST UNIT