ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-790/
(
B
)
/H
(
B
)
15. MSK
1) CH-SIG : 1-9
Power meter Rear
ANT
Panel
PF3 key Wide
±
3.0kHz
±
0.1kHz
deviation
Select MSDV_XXX
Deviation
PF4 key
in tune mode
meter
PTT : ON
AF VTVM
Panel
MIC
Deviation meter filter
AG
HPF : OFF
Oscilloscope
LPF : 15kHz
De-emphasis : OFF
2) Up/down knob : Set the narrow
Narrow
±
1.5kHz
±
0.05kHz
n_ _
MSDV_XXX in tune mode
PTT : ON
16. Sensitivity
1) CH-SIG : 2-1
SSG
Rear
ANT
Wide low check
SINAD 12dB or more
Select _ _L
SENS_XXX
AF VTVM
EXT.SP
in tune mode
Distortion
SSG output : –116dBm/0.35
µ
V meter
AF output : 2V/4
Ω
Oscilloscope
4
Ω
dummy
2) CH-SIG : 1-1
load
Wide center check
Select _ _C
SENS_XXX
in tune mode
3) CH-SIG : 3-1
Wide high check
Select _ _H
SENS_XXX
in tune mode
4) CH-SIG : 1-1
Narrow center check
Up/down knob : Set the narrow
n_C
SENS_XXX in tune mode
17. Squelch
1) CH-SIG : 1-1
Adjust to point of
Set the value to 255.
tight point
Select SQ_T_XXX
opening squelch
Adjust the SSG output to
in tune mode
“Condition”.
SSG output : Value when 6dB
Then, decrease the value to
is added from the sensitivity
the point of opening the
value of 12dB SINAD.
squelch.
2) Up/down knob : Set the narrow
n_ _
SQ_T_XXX in tune mode
18. Squelch
1) CH-SIG : 1-1
open point
Select SQ_O_XXX
in tune mode
SSG output : Value when 3dB
is subtracted from the
sensitivity value of 12dB
SINAD.
2) Up/down knob : Set the narrow
n_ _
SQ_O_XXX in tune mode
3) SSG output : OFF
Wide/Narrow check
Squelch must be closed.