17
DPX304/DPX308U/DPX404U
DPX-MP3120/U5120/U5120S
TEST MODE
w
TUNER setting adjustment mode (MANUAL)
Key
Description of display
Description
Normal display
M
S
–
x
x
L
–
x
x
[Level Offset adjustment (Manual)]
S-xx: Current S-meter value (Hex)
L-xx: Level offset value (Hex)
*
When the level offset value is not adjusted (0xFF or
0x00), “– –” is displayed.
/
■
/
Level Offset
adjustment
(Manual)
M
S
–
x
x
L
–
x
x
Press [
]/[
] key for 500ms or longer to continuously
increase/ decrease the adjustment value.
ENTER
Completion of
the adjustment
value saving
Level offset value
A
D
J
O
K
: X
X
Displayed when an adjustment value(s) was written to
the data
fl
ash. The level offset value (Hex) is displayed.
Failed to save
the adjustment
value
A
D
J
N
G
Displayed when adjustment value(s) was not written to
the data
fl
ash.
DISP
Adjustment mode
switching
Press the key brie
fl
y to enter the TUNER setting ad-
justment mode (AUTO).
ATT
Adjustment mode
switching
Press the key brie
fl
y to enter the TUNER setting ad-
justment mode (AUTO).
RETURN
Mode clear
Clear the adjustment mode to transfer to the TUNER
special display mode.
S-meter voltage evaluation mode
This mode is to display the S-meter present voltage (Hex) and to check and evaluate if the voltage is within the criteria or not (OK
or NG).
Check and evaluate the voltage only after the completion of the TUNER setting adjustment. (When the setting is not yet ad-
justed, “– –” is displayed.)
When receiving AM, do not select this mode.
When this mode, the BAND switching and SEEK operations such as operation of [BAND], [
]/[
], and [PRESET] keys shall be
prohibited.
Key
Description of display
Description
S-meter voltage
evaluation display
S-meter Evaluation
value result
S
–
M
T
R
X
X : O
K
[S-meter value]
XX: Current S-meter value (Hex)
[S-meter value evaluation result]
OK: S-meter voltage is within the range of the criteria
(J type: 0xA5~0xAF)
(Other than J type: 0xA3-0xAD)
NG: S-meter voltage is outside the range of the crite-
ria (Other than de
fi
ned above)
– –: TUNER setting is not yet adjusted
RETURN
Mode clear
Clear the adjustment mode to transfer to the TUNER
special display mode.