![Kenwood DPX-MP3120 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/kenwood/dpx-mp3120/dpx-mp3120_service-manual_188573013.webp)
13
DPX304/DPX308U/DPX404U
DPX-MP3120/U5120/U5120S
TEST MODE
Key
Description of display
Description
Forced Power
OFF information
display
P
O
F
F
#
#
#
Forced Power OFF information display
The display of ## in the left is as follows.
No forced POWER OFF: – – –
Communication error between system
μ
-com and
panel: PNL
■
Forced Power
OFF information
initialization
In the forced Power OFF information display, press
and hold this key for 2 seconds to clear Power OFF
information.
Audio data
initialization
A
U
D
I
O
I
N
I
T
AUDIO setting values are reset to the default values in
the test mode.
DISP
CD information
display mode
ON
Transfer to the CD information display mode (sub-
mode).
*
For the details of display and operation procedure,
refer to the “CD information display mode”.
■
ENTER
All of the CD
information
initialization
Press and hold this key for 2 seconds in respective
service information displays to clear all of the CD
information.
1
(forward
rotation)
System
μ
-com
version display
S
Y
S
0
1
–
3 . 0
0
System
μ
-com version display
MID: SYS03-x.xx
LOW: SYS04-x.xx
DOP information
display
D
O
P
: 0
0
0
1
DOP information display
*
Displays DOP type in 4 digits.
*
Displays “– – – –” for Kenwood brand model.
(Pressing [PRESET-1] key brie
fl
y again, MID model
transfers to the mechanism model name and mecha-
nism version display, and LOW model transfers to the
all lights ON display)
Mechanism
model name
Mechanism
version display
9
B
2
0
:
Mechanism model name and mechanism version
display
*
Displayed only in MID model.
(Pressing [PRESET-1] key brie
fl
y again, it transfers to
the all lights ON display)
■
1
Version display
mode ON
Press and hold this key for 1 second to display the
version.
*
For the details of display and operation procedure,
refer to the “Version information display mode”.
2
ROM correction
version display
System
μ
-com Mechanism
μ
-com
S
R
0
0
0
1
M
R
0
0
0
1
The number indicates ROM correction number.
*
In LOW model, there is no mechanism
μ
-com ROM
correction version display
System
μ
-com Mechanism
μ
-com
S
R
–
–
–
–
M
R
–
–
–
–
When not written-in
System
μ
-com Mechanism
μ
-com
S
R
∗
∗
∗
∗
M
R
∗
∗
∗
∗
When the data is incompatible
*
Different version
3
Power ON time
display
P
O
N
T
M :
0
H
X
X
Displays 00~50 in “XX”. Displays it for less than 1 hour
in the unit of 10 minutes.
P
O
N
T
M :
X
X
X
X
X
Displays 00001~10922 in “XXXXX”. MAX 10922 (hour)
■
3
Power ON time
information
initialization
P
O
N
T
M :
0
H
0
0
Press and hold this key for 2 seconds in the Power
ON time display, to clear Power ON time