36
LUBRICATION OF THE GAS TAPS
•
In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation maintenance of the appliance must be fulfilled
with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
BURNERS
Nominal
power
[kW]
Reduced
power
[kW]
LPG
G30 28-30 mbar
G31 37 mbar
Natural Gas
G20 20 mbar
Ø
injector
[1/100 mm]
Air ring
opening
[mm]
Ø
injector
[1/100 mm]
Air ring
opening
[mm]
Auxiliary (A)
1,00
0,30
50
-
77
-
Semi-rapid (SR)
1,75
0,45
66
-
101
-
Rapid (R)
3,00
0,75
87
-
129
-
Triple-ring (TR)
3,50
1,50
93
-
135
-
Oven
6,20
1,30
120
8 (*)
180
1,5 (*)
Grill
4,65
-
107
Fully open (*)
165
3 (*)
(*) = Reference value
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Auxiliary (A)
2,00
Semi-rapid (SR)
3,50
Rapid (R)
6,00
Triple-ring (TR)
7,00
Oven
12,40
Grill
9,30
TABLE FOR THE CHOICE OF THE INJECTORS
GB
Cat:
II
2H3+