attached  USB  device  as  the  5V  is  passed  on  to  the  attached  USB  device  for  buss  power.  There  is 
protection  circuitry  inside  the MIDI USB Host to protect against reverse polarity and over-voltage, but 
these should be treated as a last resort and are not guaranteed to prevent damage to an attached USB 
device in the event of over-voltage as the USB buss voltage could rise to 6.5V before being clamped.  
Care should be taken to ensure that power adaptors for other pieces of equipment are not accidentally 
plugged into the MIDI USB Host.  
If the input voltage rises above 6.5 volts then power will be shut off. The LED will go out and the unit 
will not operate again until power has been removed for at least 60 seconds. This allows time for the 
thermal fuse to reset. 
 

Firmware version Request

 
You  can  send  a  SysEx  message  to  request  the  version  number  of  the  firmware  currently  installed  in 
the unit.  
 
The firmware version request message is - F0 00 20 13 13 60 F7 (hex) 
 
The unit replies with the version number as F0 00 20 13 13 6F xx xx xx xx F7 (hex). 
Where xx is a number in ASCII and the leftmost digit is the most significant. 
For example - F0 00 20 13 0E 6F 31 32 33 34 F7 (hex) = version number 1234 

 