background image

TEKAPO INSTALLATION

Points to consider before Installation, and Assembly.

• 

Location of the fire. The position of the fire will have an effect on how it operates, 

consideration such as wind, boundary fences and buildings, even trees will have to 

be taken into account. It must sit on a non-combustible base such as concrete, stone, 

gravel or brick.  Putting it on a wood deck can be dangerous if embers fly out.

• 

Care needs to be taken that the flue termination is in the best position as wind, and 

gusts that hit it may overcome the cowl, and draft back down the flue can cause 

smoke to spill out of the fire mouth. Try not to put your outdoor fire close to your home 

exterior or other substantial structure where swirling eddy currents are likely there.

Select a location considering the minimum clearance required, (

Refer Table 1

) and in a 

location you can see it at all times. Never leave a fire unattended while in operation.

An insulating floor protector is not required for this fire, but the fire base frame must sit on 

a  continuous  layer  of  non-combustible  material  extending  out  a  minimum  of  500mm, 

in front of the fireplace and 200mm to each side of the appliance, that is capable of 

withstanding the weight of the fire, fuel and any other object in close proximity. It must 

have a 300mm clearance from the back of the fire to any other object.

Minimum Installation Clearances (mm)

A

B

C

D

E

F

G

H

I

J

300

1000

500

200

300

484

1470

1340

950

826

TABLE 1

Corner Clearances

Wall Clearances

A

G

B

H

J

C

D

F

D

I

J

C

H

D

D

E

E

3

SPECIFICATIONS

Construction: 

4mm Matt Black Mild steel

Dimensions (mm):

 2930H x 995 W x 520 D

Weight (kg):

 186

Pizza Stone (mm):

 300 x 300

Stainless Steel Grill (mm): 

320 x 485

Hotplate (mm): 

320 x 320

Содержание Tekapo

Страница 1: ...ns 3 Installation 3 7 Operation 10 11 Maintenance and care 12 Parts and accessories 13 14 Warranty 15 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Important the installer or seller must leave these...

Страница 2: ...place while not in use Chimney extensions are also available if required from your Kent stockist 1 This Kent freestanding fire must be installed according to these instructions Do not allow any makesh...

Страница 3: ...a location considering the minimum clearance required Refer Table 1 and in a location you can see it at all times Never leave a fire unattended while in operation An insulating floor protector is not...

Страница 4: ...th fire flue sealer including the flue pipe connecting to the flue stub on the fire 2 Install crimped end of these assembled sections of flue into the spigot on top of the fire box 3 Place the 250mm b...

Страница 5: ...cured until heated A fire too hot too fast will burn the paint off before it has fully cured Often for the fire to burn properly you will need to burn the fire for 15 20 minutes to get the chimney up...

Страница 6: ...r scratches occur it can be easily touched up using stove paint Any rust or other stubborn marks that may appear can be removed with the help of steel wool and hot soapy water and re painted if necess...

Страница 7: ...n accordance with the manufacturer s instructions and all applicable standards regulations and by laws Your Kent wood fire must be installed with an approved flue system Subject to any statutory provi...

Страница 8: ...ngs Ltd T A Aber 17 Mainstreet Place Te Rapa Hamilton 3200 Free Phone 0800 161 161 Free Fax 0800 163 163 www aber co nz Product specifications are at date of publication and are subject to change with...

Отзывы: