background image

                                             

 

#3.  ASSEMBLING THE KWIK & EZ FILLER MACHINE TO 

TABLE 

( If you are supplying your own table or stand go to #5 at this time.) 

 

1.

 

Unpack the Kwik & EZ unit. Inspect for any damage that could have occurred 
during shipping. 

 

2.

 

Remove tabletop and set aside. 

 
 

3.

 

Place the 

Kwik & EZ Filler Machine 

on the table, matching the four holes of the 

Kwik & EZ Filler Machine with the corresponding four holes of the table.  

 
 

 
4.

 

 Using the four bolts and washer provided secure the Kwik & EZ to the tabletop.   

 

5.

 

THIS MACHINE MUST BE GROUNDED BY A LICENSED 
ELECTRICIAN BEFORE YOU CONTINUE.  

FAILING TO DO THIS 

WILL CAUSE AN UNSAFE CONDITION AND COULD CAUSE INJURY 
OR DEATH.

 

 

6.

 

Connect the ground cable to the container of chemical you are using. Clamp needs 
a bare metal connection.  

You will

 

need to reconnect the ground every time 

you change the container

. (Diagram #1) 

 

 

 

 

Diagram #1 

 

 
7.

 

 Install the air filter and nipple provided on to the elbow at the top of the machine. 
(Diagram #2)  Do this at the same time you install your quick connect nipple on to 

Содержание S400A

Страница 1: ...th the special filler cap Part KT14733 it is chemically resistant to almost any product This unit is set up to dispense products in AERO miser applicators which have a 32 oz capacity DO NOT use this machine for any other size applicator Do not use Steel sprayers with water based materials IMPORTANT Excessive moisture and debris in your air line can cause damage to this piece of equipment and may v...

Страница 2: ...TABLE OF CONTENTS Introduction 1 Safety Information 2 Assembly 3 Start up 4 ...

Страница 3: ...comes with special seals to cover a wide range of chemicals It is easy to use and built to industrial specifications Properly maintained it will provide years of trouble free service EXPLOSION HAZARD WARNING 1 The Kwik EZ Fill machine MUST be grounded by a licensed electrician to prevent the possibility of electrostatic discharge which can lead to the explosion of solvent containing vapors 2 Keep ...

Страница 4: ...This machine is designed exclusively for use with AERO miser applicators Use of any other equipment with this machine voids warranty and can cause a dangerous situation injury or death 6 DO NOT remove or cover any warning labels or instructions on this machine 7 DO NOT kink bend or twist any hoses 8 DO NOT refill the applicator unless it is completely empty of air and liquid 9 DO NOT refill unless...

Страница 5: ... the four bolts and washer provided secure the Kwik EZ to the tabletop 5 THIS MACHINE MUST BE GROUNDED BY A LICENSED ELECTRICIAN BEFORE YOU CONTINUE FAILING TO DO THIS WILL CAUSE AN UNSAFE CONDITION AND COULD CAUSE INJURY OR DEATH 6 Connect the ground cable to the container of chemical you are using Clamp needs a bare metal connection You will need to reconnect the ground every time you change the...

Страница 6: ...only be removed for cleaning 11 The compression fitting for the siphon tube has been installed facing to the front of the machine To change position hold the fitting using a 1 or adjustable wrench and tighten the compression fitting using a 9 16 wrench to the desired position that you would like the siphon tube to enter the compression fitting from Diagram 3 This will depend on where you locate yo...

Страница 7: ... with 125 P S I of air AND siphon the chemical back into the pump so you are ready for the next fill If you do not hold the Joystick to the left long enough the rod will retract slightly indicating a short fill If this happens push the Joystick back to the left for an additional 5 seconds and release 4 Disconnect the quick connect from top of sprayer by pulling the outside collar of the quick conn...

Страница 8: ......