UF  Process

KENT Ultra Filtration is a separation process that uses UF membrane with pore size of  0.1–0.01 
micron. This UF membrane has the capacity to remove colloidal materials including bacteria, cyst 
and even viruses from drinking water. Low applied pressure is therefore sufficient to achieve high 
flux rates from an Ultra Filtration membrane.

Refrigeration  Process

The  refrigeration  cycle  is  a  common  method  for  transferring  heat  from  low  temperature  to  high 
temperature.  The four basic components of  refrigeration cycle are:

• Compressor: 

The compressor serves two functions. It compresses the low-pressure, low-temperature 

gas into a high pressure, high-temperature gas and it keeps the refrigerant flowing through the cycle.

• Condenser: 

The condenser receives hot pressurised 

refrigerant gas from the compressor and cools it until 
the  gas  changes  to  a  liquid  state.  In  doing  so,  the 
condenser transfers heat from the refrigerant into the 
air surrounding the condenser coils.         

• Capillary  Tube: 

The  capillary  tube  measures  the 

amount of  refrigerant released to the evaporator (coil 
type). They appear in the refrigeration cycle just before 
the  evaporator  (coil  type).    If   the  capillary  tube  is 
restricted,  the  proper  flow  of   refrigerant  will  be 
disturbed and the water will not be adequately cooled.

• Evaporator  (Coil  Type): 

Refrigerant  changes  from 

liquid  to  gas  in  the  evaporator  and  once  again  the 
refrigeration cycle begins.

Auto-Flushing  System

The purpose of  the Auto Flushing system is to help prevent scaling or fouling of  the RO membrane by 
providing  a  rapid  rinse  which  washes  away  impurities  from  the  membrane's  surface  and  keeps  the 
membrane clean.  It also offers the following benefits:

Lowers reject water outflow  

Improves  "TDS" rejection rate i.e. increases RO membrane efficiency

Extends life of  RO membrane.

KENT 

Perk Chiller Cum Water Dispenser with in-built RO Purifier

Marketed by:

KENT RO SYSTEMS LTD.

 

A-2, Sector-59, Noida, U.P.-201 309, India

Ph.: +91-120-3075075

E-mail: [email protected]  Website: www.kent.co.in 

Customer Care: +91-120-4669666

:

:

:

:

:

:

:

:

:

(For sale through dealer)

Filter  Change  Alarm*

KENT

 

Perk Chiller Cum Water Dispenser with in-built RO Purifier has an in-built feature that sounds an 

audible alarm to indicate replacement time for filters. This alarm will be audible after 

 The  Filter  Change  Alarm  will  sound  as 

following: 4 short  beeps  after  every  2  sec  for 30  sec.  The  alarm  will  repeat  after every  2 hrs  of use.

In case such an alarm is audible, please call the service technician and request him to change the filters of the 
purifier. However, if the filters are not changed within the next 60 hours of operation, the purifier   will   stop   
functioning  to  ensure  purity  and  hygiene.  The  following  alarm  will  be  audible  after  60 Hrs.  A continuous 
beep for an infinite time.

In case, such an alarm is audible, kindly switch off  the purifier and call the service technician to replace 
the  filters.  In  such  a  circumstance,  the  purifier  will  not  function  unless  the  filters  are  changed.

700 hrs of  use 

since the last filter change (or since the time of  installation).

2  Hours

30  Sec.

30  Sec.

Содержание PERK

Страница 1: ...rocess purifier is patented vide patent no 199716 KENT Perk s design is registered vide registration no 219309 Reverse Osmosis Water Purifier TDS Controller January 2015 For customer complaints contac...

Страница 2: ...wards acquainting you with operation and maintenance of KENT Perk Chiller Cum Water Dispenser with in built RO Purifier Read this manual carefully prior to using the product for easy operation of the...

Страница 3: ...process reduces salts from potable or brackish water When pressure is applied purer water gets squeezed through the membrane from the concentrated side to the diluted side Salts dissolved in water beh...

Страница 4: ...ng System The purpose of the Auto Flushing system is to help prevent scaling or fouling of the RO membrane by providing a rapid rinse which washes away impurities from the membrane s surface and keeps...

Страница 5: ...to other reasons such as transportation strikes labour disputes with outside suppliers or due to reasons beyond the control of KENT or its ASP They shall not be forced to abide by any obligations of t...

Страница 6: ...ter Invoice No Invoice Date Installation Date Service Provider s Name Service Provider s Address Service Provider s Ph TDS of Raw Water By signing on this installation report the customer hereby agree...

Страница 7: ...the S S ball valve to the inch port of the 3 way connector as shown in the figure 3 Connect the 3 way connector to the raw water supply as shown in the figure The threaded end of the 3 way connector i...

Страница 8: ...time due to clogging of pores of membranes This reverse osmosis system contains a replaceable component critical to the efficiency of the purifiers Replacement of the reverse osmosis component should...

Отзывы: