21
*If various materials have to be grounded, so that the wheel has to be changed frequently, it is
more advantageous to change the wheel completely with a flange. It would save you time from
removing the wheel from its mount each time to re-balance and re-dress it.
E)
Putting The Machine Into Operation
(1).Wiring of power source
Be sure that the wire connection is same as your power source before you power "ON" the
machine.
Box B
Box A
Box C
Box A: Electric cabinet
Box B: Three-phase transformer for:
1. Cross motor
2. Solenoid valve
3. Electromagnetic chuck
4. Auto lubrication pump
Box C: Control panel and control circuit
Attention:Following motors must be wired in accordance with power source voltage.
1.
Spindle motor
2.Hydraulic motor
3.Coolant or dust-collector motor(Optional accessory)
a.
For 440V power source:
Box B
Box A
460
460
460
210
210
210
U6 V6 W6
U V W
Power Source