7
5.
6.
7.
(I)
(ii)
Now connect one end of the white pipe to the SS ball valve and other end to the
lower pushfit elbow fitting on the left hand side of the purifier labeled as
WATER IN (Note : White pipe is for raw water supply).
Similarly, connect one end of the blue pipe to the upper elbow fitting
connector labeled as REJECT WATER and leave the other end in the
drain (Note : Blue pipe is for reject water).
Before connecting the power supply, it is important that you perform the
following functions:
Open the SS ball valve (Handle parallel to the ball valve) to start the
flow of water into the purifier.
Wait for 2-3 minutes to ensure that the filters are soaked in water.
TDS Adjustment*
8
The reverse osmosis system contains a replaceable treatment component critical for the effective reduction
of total dissolved solids and that product water is tested periodically to verify that the system is performing
properly.
Replacements of spare parts are as under:-
To ensure that the purifier operates at its
after every 12 months. It is recommended to
optimum level, a routine maintenance must be
change the FRT when the filters are replaced
performed. The frequency of the maintenance will
Replace the RO membrane once in a year
and greatly depend upon the raw water quality and
Replace the UV Lamp once in a year
consumption of treated water.
If you are not going to use the purifier for a long
Storage tank must be drained once in 2 weeks. To
time ( in case you are on a holiday, tour or out of
do so, switch off the power supply, open the drain
home), make sure that you disconnect the power
plug at the bottom of the tank and allow the water
supply, turn off the raw water supply and drain
to drain. Then screw back the plug and switch on
the storage tank
the power supply
Replace sediment, activated carbon and post
carbon when the filter change alarm is audible or
n
n
n
n
n
Maintenance
n
n
n
n
n
n
Switch on the power supply
as to remove any dust particles present in the
pipes and storage tank
Wait till the storage tank fully fills up**
Close the drain plug & switch on the power supply
Switch off the power supply
The purifier is ready to use
Drain the storage tank by opening the drain
plug present at the bottom of the storage tank so
Starting Up the Purifier
Although the rejected water has high concentration
minerals which accelerate plant growth. Rejected
of salts. This rejected water usually goes down the
water can also be used for cleaning purposes, i.e.
drain but if required, can be used for gardening
utensils cleaning, mopping, etc.
purposes. It has high concentration of salts and
Recommended Uses of Reject Water
* Tested & Certified by TUV-SUD South Asia (P) Ltd.
** Tested or certified flushing time - 24hrs.
Note: Filters and membrane are consumables. Their replacement time is dependent on the quality of raw
water and water consumption. They are not covered under the warranty. However, if a filter chokes within six
months and a membrane within a year, it will be cleaned/repaired/replaced free of cost. Changing the filters
and system inspection is available on call. The treatment capacity of RO membrane will reduce with time due
to clogging of pores of membranes.
“This reverse osmosis system contains a replaceable component critical to the efficiency of the system.
Replacement of the reverse osmosis component should be with one of identical specifications as defined by
the manufacturer, to ensure the same efficiency and contaminant reduction performance.”
-20010
SP Inline Sediment Filter 8"
-20009
SP Inline Carbon Filter 8"
-20001
SP RO Membrane Welded 10" Housing
-20015
SP Post Carbon Filter (Blue)
-20003
SP Hollow Fibre Membrane (RO)
-20018
SP FRT 550
The unique TDS Controller enables customers to retain the contents of natural minerals in purified water as per
their requirement.
n
Turning the screw of the valve anti-clockwise
results in an increased mineral content
n
Turning the screw of the valve clockwise results
in a decreased mineral content